lpc2939fbd208 NXP Semiconductors, lpc2939fbd208 Datasheet - Page 54

no-image

lpc2939fbd208

Manufacturer Part Number
lpc2939fbd208
Description
Arm9 Microcontroller With Can, Lin, And Usb
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPC2939FBD208
Manufacturer:
NXP
Quantity:
105 000
Company:
Part Number:
LPC2939FBD208
Quantity:
72
Part Number:
lpc2939fbd208,551
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
LPC2939_1
Preliminary data sheet
Configuration of the CGU0:
choice can be made from the primary and secondary clock generators according to
Figure
Any output generator (except for BASE_SAFE_CLK and BASE_PCR_CLK) can be
connected to either a fractional divider (FDIV0:6) or to one of the outputs of the PLL or to
LP_OSC/crystal oscillator directly. BASE_SAFE_CLK and BASE_PCR_CLK can use only
LP_OSC as source.
The fractional dividers can be connected to one of the outputs of the PLL or directly to
LP_OSC/crystal Oscillator.
The PLL is connected to the crystal oscillator.
In this way every output generating the base clocks can be configured to get the required
clock. Multiple output generators can be connected to the same primary or secondary
clock source, and multiple secondary clock sources can be connected to the same PLL
output or primary clock source.
Invalid selections/programming - connecting the PLL to an FDIV or to one of the PLL
outputs itself for example - will be blocked by hardware. The control register will not be
written, the previous value will be kept, although all other fields will be written with new
data. This prevents clocks being blocked by incorrect programming.
Default Clock Sources:
connected to LP_OSC at reset. In this way the device runs at a low frequency after reset.
It is recommended to switch BASE_SYS_CLK to a high-frequency clock generator as
(one of) the first step(s) in the boot code after verifying that the high-frequency clock
generator is running.
Clock Activity Detection:
and values of ‘CLK_SEL’ that would select those clocks are masked and not written to the
control registers. This is accomplished by adding a clock detector to every clock
Fig 13. Structure of the clock generation scheme
13.
OSCILLATOR
EXTERNAL
LP_OSC
Rev. 01 — 11 June 2009
Every secondary clock generator or output generator is
Clocks that are inactive are automatically regarded as invalid,
For every output generator generating the base clocks a
PLL
ARM9 microcontroller with CAN, LIN, and USB
clkout
clkout120
clkout240
CONTROL
OUTPUT
outputs
clock
LPC2939
© NXP B.V. 2009. All rights reserved.
FDIV0:6
002aad834
54 of 98

Related parts for lpc2939fbd208