5 Pin list
Table 16 is a list of all the pins and their functionalities.
Pad
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Contact:
Cypress Semiconductor Corporation
LUPA-4000
Data Sheet
Pin
E1
F1
D2
G2
G1
F2
H1
H2
J2
J1
K1
M2
L1
M1
N2
P1
P2
N1
P3
Q1
Q2
R1
R2
Q3
Q4
N3
Q5
Q6
info@Fillfactory.com
Pin Name
sync_x
eos_x
vdd
clock_x
eos_spi
spi_data
spi_load
spi_clock
gndo
out2
out2DC
voo
out1DC
out1
gndo
vaa
gnda
va3
vpix
psf_load
nsf_load
muxbus_load
uni_load_fast
pre_load
out_load
dec_x_load
uni_load
col_load
Pin Type
Input
Testpin
Supply
Input
Testpin
Input
Input
Input
Ground
Output
Output
Supply
Output
Output
Ground
Supply
Ground
Supply
Supply
Input
Input
Input
Input
Input
Input
Input
Input
Input
Document #: 38-05712 Rev.**(Revision 1.2 )
3901 North First Street
Table 16: Pin list
Description
Digital input. Synchronises the X-address register.
Power supply digital modules.
Digital input. Determines the pixel rate.
Checks if the data is transferred correctly through the
SPI.
Digital input. Data for the SPI.
Digital input. Loads data into the SPI.
Digital input. Clock for the SPI.
Ground output stages
Analog output 2.
Reference output 2.
Power supply output stages
Reference output 1.
Analog output 1.
Ground output stages.
Power supply analog modules.
Ground analog modules.
Power supply column modules.
Power supply pixel array.
Analog reference input. Biasing for column modules.
Connect with R=1MΩ to Vaa and decouple with
C=100nF to gnda.
Analog reference input. Biasing for column modules.
Connect with R=5kΩ to Vaa and decouple with
C=100nF to gnda.
Analog reference input. Biasing for multiplex bus.
Connect with R=25kΩ to Vaa and decouple with
C=100nF to gnda.
Analog reference input. Biasing for column modules.
Connect with R=10kΩ to Vaa and decouple with
C=100nF to gnda.
Analog reference input. Biasing for column modules.
Connect with R=3kΩ to Vaa and decouple with
C=100nF to gnda.
Analog reference input. Biasing for output stage.
Connect with R=60kΩ to Vaa and decouple with
C=100nF to gnda.
Analog reference input. Biasing for X-addressing.
Connect with R=2MΩ to Vdd and decouple with
C=100nF to gndd.
Analog reference input. Biasing for column modules.
Connect with R=1MΩ to Vaa and decouple with
C=100nF to gnda.
Analog reference input. Biasing for column modules.
Connect with R=1MΩ to Vaa and decouple with
C=100nF to gnda.
Indicates when the end of the line is reached.
San Jose, CA 95134
Page 36 of 49
408-943-2600

Related parts for LUPA-4000