X4043 INTERSIL [Intersil Corporation], X4043 Datasheet - Page 14

no-image

X4043

Manufacturer Part Number
X4043
Description
CPU Supervisor with 4kbit EEPROM
Manufacturer
INTERSIL [Intersil Corporation]
Datasheets

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
X4043
Manufacturer:
XICOR
Quantity:
20 000
Part Number:
X40430S14-A
Manufacturer:
Intersil
Quantity:
200
Part Number:
X40430S14I-A
Manufacturer:
Intersil
Quantity:
92
Part Number:
X40430S14I-B
Manufacturer:
Intersil
Quantity:
96
Part Number:
X40431S14-A
Manufacturer:
Intersil
Quantity:
500
Part Number:
X40431S14-B
Manufacturer:
Intersil
Quantity:
100
Part Number:
X4043PI
Manufacturer:
INTERSIL
Quantity:
20 000
Company:
Part Number:
X4043S8-2.7
Quantity:
2 870
Part Number:
X4043S8IZ
Manufacturer:
INTERSIL
Quantity:
20 000
Random Read
Random read operation allows the master to access
any memory location in the array. Prior to issuing the
slave address byte with the R/W bit set to one, the
master must first perform a “dummy” write operation.
The master issues the start condition and the slave
address byte, receives an acknowledge, then issues
the word address bytes. After acknowledging receipts
Figure 15. Random Address Read Sequence
There is a similar operation, called “Set Current
Address” where the device does no operation, but
enters a new address into the address counter if a
stop is issued instead of the second start shown in Fig-
ure 14. The device goes into standby mode after the
stop and all bus activity will be ignored until a start is
detected. The next current address read operation
reads from the newly loaded address. This operation
could be useful if the master knows the next address it
needs to read, but is not ready for the data.
Sequential Read
Sequential reads can be initiated as either a current
address read or random address read. The first data
byte is transmitted as with the other modes; however,
Figure 16. Sequential Read Sequence
Signals from
Signals from
the Master
the Slave
SDA Bus
Signals from
Signals from
the Master
the Slave
SDA Bus
Address
14
Slave
S
a
r
t
t
1
C
A
K
Address
Slave
Data
(1)
0
C
A
K
X4043, X4045
Address
A
C
K
Byte
Data
(2)
C
A
K
of the word address bytes, the master immediately
issues another start condition and the slave address
byte with the R/W bit set to one. This is followed by an
acknowledge from the device and then by the eight bit
word. The master terminates the read operation by not
responding with an acknowledge and then issuing a
stop condition. Refer to Figure 15 for the address,
acknowledge, and data transfer sequence.
the master now responds with an acknowledge, indicat-
ing it requires additional data. The device continues to
output data for each acknowledge received. The master
terminates the read operation by not responding with an
acknowledge and then issuing a stop condition.
The data output is sequential, with the data from address
n followed by the data from address n + 1. The address
counter for read operations increments through all page
and column addresses, allowing the entire memory con-
tents to be serially read during one operation. At the end
of the address space the counter “rolls over” to address
0000
acknowledge received. Refer to Figure 16 for the
acknowledge and data transfer sequence.
S
a
r
t
t
H
Address
and the device continues to output data for each
A
C
K
Slave
(n is any integer greater than 1)
Data
(n-1)
1
A
C
K
Data
A
C
K
Data
(n)
S
o
p
t
September 30, 2005
S
o
p
t
FN8118.1

Related parts for X4043