10.5.1
There are two ways of connecting the incoming mains to a power-level terminal:
You can connect the incoming mains using a power connector.
When assembling the power connector, proceed as shown in Figure 10-10:
Figure 10-10
Figure 10-11
WARNING: Dangerous contact voltage
Only remove or insert the power connector or the power bridge when the mains voltage is
disconnected.
X11
X12
Strip approximately 80 mm off the cable sheath (detail A) and 7 mm off the wires
(detail B). Fit the wire ends with ferrules.
Connect the wires to the connector (detail C). The assignment is shown in
Figure 10-11.
Incoming mains
Outgoing mains
Connecting or forwarding the incoming mains
Assembling a power connector
Power connector assignment