ZUP36-12/U TDK Corporation, ZUP36-12/U Datasheet - Page 30

PWR SUP BENCH PROG 0-36V 432W

ZUP36-12/U

Manufacturer Part Number
ZUP36-12/U
Description
PWR SUP BENCH PROG 0-36V 432W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Enclosedr
Datasheets

Specifications of ZUP36-12/U

Number Of Outputs
1
Efficiency
84%
Voltage - Output
0 ~ 36V
Power (watts)
432W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 36 VDC @ 12A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
432W
Operating Temperature
0°C ~ 50°C
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Output Current (max)
12A
Input Voltage
85 to 265V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Accuracy
0.02% + 20 mV
Brand/series
ZUP
Current, Output
12 A
Display Type
Digital Meter
Power, Output
432 W
Power, Rating
432 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
36 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1676
ZUP3612/U
4
2
3
4.2.2
Table 4-1 contd.: Front panel controls and indicators
10
11
12
13
#
Control/Indicator
AC ON/OFF
V/A Pushbutton
ADDR
OVP / UVP
6V to 60V models
Rear Panel
5
Fig. 4-2: Rear panel connections
Description
Turns AC power On and Off.
Selects the voltage or current adjust mode. fast or slow
adjustment speed can be selected by pressing the
pushbutton consecutively. Adjustment is made by rotating
the Adjust knob.
Makes selection between Over-voltage or Under-voltage
adjust mode. Adjustment is made by rotating the Adjust
knob.
Main function: Selects the address for remote control. The
adjustment is made by rotating the Adjust knob.
Auxiliary function: Holding ADDR pressed for approx. 3sec.
changes the function to Baud-rate selection.
6
1
80V and 120V models
4.4.5
4.4.6
4.4.2
4.4.3
5.2.1
5.2.3
Par.
6

Related parts for ZUP36-12/U