ZUP36-12/U TDK Corporation, ZUP36-12/U Datasheet - Page 50

PWR SUP BENCH PROG 0-36V 432W

ZUP36-12/U

Manufacturer Part Number
ZUP36-12/U
Description
PWR SUP BENCH PROG 0-36V 432W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Enclosedr
Datasheets

Specifications of ZUP36-12/U

Number Of Outputs
1
Efficiency
84%
Voltage - Output
0 ~ 36V
Power (watts)
432W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 36 VDC @ 12A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
432W
Operating Temperature
0°C ~ 50°C
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Output Current (max)
12A
Input Voltage
85 to 265V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Accuracy
0.02% + 20 mV
Brand/series
ZUP
Current, Output
12 A
Display Type
Digital Meter
Power, Output
432 W
Power, Rating
432 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
36 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1676
ZUP3612/U
5.5.3 Output control continued
10
12
11
#
5
6
7
8
9
:CUR!;
:CUR?;
:OVPn;
Commands
:FLD?;
:OVP?;
:OUTn;
:OUT?;
:FLDn;
Example - ZUP10-XY :OVP08.4;
Example- OP08.4
Description
Returns the string
output current. The programmed value range is shown in table 5-2.
example- SA3.000 SA07.50
Returns the string
The actual current range is the same as the programming range.
example- AA3.000 AA07.50
Sets the output to On or Off.
:OUT1; - Output On
:OUT0; - Output Off
Returns
OT1 - Output is On
OT0 - Output is Off
Sets the Foldback protection to On or Off.
:FLD1; Arm the foldback protection.
:FLD0; Release the foldback protection.
:FLD2; Cancel the foldback protection.
When the foldback protection is activated, :FLD0; will release the
protection and re-arm it while :FLD2; will cancel the protection. If the
protection has not been activated, both commands are the same.
Returns
FD1 - Foldback is armed
FD0 - Foldback is released
Sets the over-voltage protection level in volts. Over-voltage range settings
are given in table 5-3:
Table 5-3: Over-voltage programming range.
Returns the string
protection value. The over-voltage range is given in table 5-3.
ZUP6-XY
ZUP10-XY
ZUP20-XY
ZUP36-XY
ZUP60-XY
Model
ZUP80-XY
ZUP120-XY 006.0 132.0
OT
FD
followed by the Foldback protection status.
followed by the output On/Off status.
MIN.
0.20
00.5
01.0
01.8
03.0
04.0
AA
OP
SA
MAX.
13.0
24.0
40.0
66.0
88.0
(Actual Amper) followed by the actual output current.
7.50
(Set Amper) followed by the present programmed
followed by the present programmed over-voltage

Related parts for ZUP36-12/U