ZUP36-12/U TDK Corporation, ZUP36-12/U Datasheet - Page 41

PWR SUP BENCH PROG 0-36V 432W

ZUP36-12/U

Manufacturer Part Number
ZUP36-12/U
Description
PWR SUP BENCH PROG 0-36V 432W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Enclosedr
Datasheets

Specifications of ZUP36-12/U

Number Of Outputs
1
Efficiency
84%
Voltage - Output
0 ~ 36V
Power (watts)
432W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 36 VDC @ 12A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
432W
Operating Temperature
0°C ~ 50°C
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Output Current (max)
12A
Input Voltage
85 to 265V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Accuracy
0.02% + 20 mV
Brand/series
ZUP
Current, Output
12 A
Display Type
Digital Meter
Power, Output
432 W
Power, Rating
432 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
36 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1676
ZUP3612/U
4.4.14 Series Operation
1. GENERAL: Two power supplies of the same rating can be connected in series to increase the
2. Series connection for increased output voltage:
current limits of each power supply to the maximum that the load can handle without damage. It is
recommended to connect diodes in parallel to each unit output to prevent reverse voltage during start-
up condition or in case one of the units shuts down. Each diode should be rated to at least the power
supply’s output current. Refer to Fig: 4-12 and 4-13 for this operating mode.
Fig. 4-12: Series connection with local sensing.
When two power supplies are connected in series, they should be programmed to the same output
2.2 Remote programming at series operation for increased output voltage:
output voltage or to provide bipolar output voltage.
2.1 General: At this operation mode, two units are connected so their outputs are summed. Set the
SUPPLY
SUPPLY
POWER
POWER
is grounded, no point may be at a greater potential ( + or - ) from ground than that specified
When power supplies are connected in series, and the load or one of the output terminals
1. Programming by external voltage; The analog programming circuits of the ZUP power supply
2. Programming by external resistor: Programming by external resistor is possible. Refer to
3. Programming via the communication port (RS232/RS485): The communication port is isolated
are referenced to the - Sense potential. Therefore, the circuits used to control each unit must
be separated and floated from each other.
Fig. 4-5 and Fig. 4-6 for details.
from the output voltage, therefore power supplies connected in series, can be chained using
the Remote-in and Remote-out connectors.
voltage to prevent damage to the lower voltage supply at short circuit condition.
+LS
+LS
- LS
- LS
+S
+S
- S
- S
+
+
_
_
on the front panel marking.
+
_
LOAD
CAUTION
CAUTION
Fig. 4-13: Series connection, remote sensing.
SUPPLY
SUPPLY
POWER
POWER
+LS
+LS
- LS
- LS
+S
+S
- S
- S
+
+
_
_
+
_
LOAD