ZUP10-40/U TDK Corporation, ZUP10-40/U Datasheet - Page 12

PWR SUP BENCH PROG 0-10V 400W

ZUP10-40/U

Manufacturer Part Number
ZUP10-40/U
Description
PWR SUP BENCH PROG 0-10V 400W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP10-40/U

Load Regulation
0.01%
Voltage - Output
0 ~ 10V
Number Of Outputs
1
Power (watts)
400W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 10 VDC @ 40A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
400W
Operating Temperature
0°C ~ 50°C
Efficiency
82%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
10V
Output Current
40A
Power Rating
400W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 8 mV
Brand/series
ZUP
Current, Output
40 A
Display Type
Digital Meter
Power, Output
400 W
Power, Rating
400 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
10 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1669
ZUP1040/U
PART No.
(NC302)
(NC303)
(NC305)
1.2.7 Cooling and mechanical construction
The Zup series is fan cooled. Upon installation take care to allow free air flow into the power supply via
the front panel and out of the power supply via the rear panel. The ZUP series is contained in a compact,
lightweight package which allows for easy installation and space saving in the application equipment.
1.3 ACCESSORIES
1.3.1 General
1.3.2 Serial link cables
1.3.3 AC Cables
1.3.4 Front Panel Outputs option
In cases where load connection at the front panel is required, optional Front Panel output Jacks for a
load current of 20A maximum is available. Please note that the power supply height is increased with
this option. Refer to outline drawing (par. 3.12) for details.
ORDER No.
ZUP
Accessories are delivered with the power supply or separately upon ordering.
Below are listed possible accessories and ordering numbers.
PART No.
NL 100
NL 200
NL 101
NL 102
(NC301)
ZUP/E
ZUP/O
Serial link cable, for linking power supplies by RS485 communication is provided with the power supply
according to order. Cable description: 0.5m typ. length, shielded, EIA-568A type plugs, 8 contacts.
Refer to par.5.3.4 , for details.
ZUP/U
ZUP/J
/L
Additional instruction manual
19” rack, 3U height
Dual output packing
Blank panel for 19” rack
DESCRIPTION
MARKET
Europe
General
Japan
USA
20A Front Panel Output Jacks
DESCRIPTION
DESCRIPTION
10A, 250V, unshielded, 2m typ. length, with IEC320 connector on one
side and INT’L 7 standard VII, dual earthing on the other side.
10A, 250V, unshielded, 2m typ. length, with IEC320 connector on one
13A, 125V unshielded, 2m typ. length, with IEC320 connector on one
13A, 125V, unshielded, 2m typ. length, with IEC320 connector on one
side and NEMA-5-15P connector the on other side.
side and unterminated stripped wires on the other side. Use the cable
side and Japan type plug on other side.
only with plug approved by the national safety standards of the country
of usage.

Related parts for ZUP10-40/U