ZUP10-40/U TDK Corporation, ZUP10-40/U Datasheet - Page 17

PWR SUP BENCH PROG 0-10V 400W

ZUP10-40/U

Manufacturer Part Number
ZUP10-40/U
Description
PWR SUP BENCH PROG 0-10V 400W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP10-40/U

Load Regulation
0.01%
Voltage - Output
0 ~ 10V
Number Of Outputs
1
Power (watts)
400W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 10 VDC @ 40A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
400W
Operating Temperature
0°C ~ 50°C
Efficiency
82%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
10V
Output Current
40A
Power Rating
400W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 8 mV
Brand/series
ZUP
Current, Output
40 A
Display Type
Digital Meter
Power, Output
400 W
Power, Rating
400 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
10 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1669
ZUP1040/U
2.2 SUPPLEMENTAL CHARACTERISTICS
The supplemental characteristics give typical but non-warranted performance characteristics. The
supplemental characteristics are useful in accessing applications for the power supply. Several kinds
of supplemental characteristics are listed below.
1. EVALUATION DATA: Typical performance of the power supply.
2. RELIABILITY DATA: Reliability performance of the power supply.
3. IEC 1000 DATA:
Performance of the power supply under IEC 1000 test conditions.
4. EMI DATA:
Typical EMI (conducted and radiated) performance of the power supply.
The supplemental characteristics data are held in each Nemic-Lambda sales and service facility. For
further details please contact the Nemic-Lambda office nearest you.

Related parts for ZUP10-40/U