ZUP10-40/U TDK Corporation, ZUP10-40/U Datasheet - Page 37

PWR SUP BENCH PROG 0-10V 400W

ZUP10-40/U

Manufacturer Part Number
ZUP10-40/U
Description
PWR SUP BENCH PROG 0-10V 400W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP10-40/U

Load Regulation
0.01%
Voltage - Output
0 ~ 10V
Number Of Outputs
1
Power (watts)
400W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 10 VDC @ 40A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
400W
Operating Temperature
0°C ~ 50°C
Efficiency
82%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
10V
Output Current
40A
Power Rating
400W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 8 mV
Brand/series
ZUP
Current, Output
40 A
Display Type
Digital Meter
Power, Output
400 W
Power, Rating
400 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
10 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1669
ZUP1040/U
4. OUTPUT VOLTAGE PROGRAMMING BY EXTERNAL RESISTOR
Fig 4-5 shows a typical set-up for programming the output voltage. A variable programming resistor,
0~4Kohm produces a proportional output voltage from zero to full scale. In order to set the low limit, a
series resistor can be connected to the programming resistor. For example; a 1kohm series resistor will
set the lower limit to 25% of full scale. In order to set the upper limit, a resistor can be connected in
parallel to the programming resistor. The resultant programming resistance of the series/parallel
resistors must be between 0 and 4Kohm.
Fig. 4-5:
Constant voltage resistive programming.
Fig. 4-6:
Constant current resistive programming.
5.OUTPUT CURRENT PROGRAMMING BY EXTERNAL RESISTOR
Fig 4-6 shows the set-up for constant current resistive programming. The explanation given for
constant voltage resistive programming also applies for constant current.
Resistive programming is possible for local and remote sensing.
sets lower
sets lower
Optional
Optional
limit
limit
programming resistor
programming resistor
0~4K
0~4K
NOTE
sets upper limit
sets upper limit
Optional
Optional
VCVP
VCCP
RCCP
COM
VCVP
VCCP
RCCP
External control connector
External control connector
- S
+S
COM
P
(ZUP rear panel view)
(ZUP rear panel view)
- S
+S
P
14
14
2
2
13
1
13
1
Output Good
Output Good
On/Off
VRFV
VRFI
RCVP
On/Off
VRFV
VRFI
RCVP
- LS
+LS
- LS
+LS