EVL6563S-400W STMicroelectronics, EVL6563S-400W Datasheet - Page 8

EVAL BOARD FOR L6563(400W)

EVL6563S-400W

Manufacturer Part Number
EVL6563S-400W
Description
EVAL BOARD FOR L6563(400W)
Manufacturer
STMicroelectronics
Type
Motor / Motion Controllers & Driversr
Datasheets

Specifications of EVL6563S-400W

Main Purpose
Power Management, Power Factor Correction
Embedded
No
Utilized Ic / Part
L6563
Primary Attributes
400W Power Factor Correction and Preregulator Combination
Secondary Attributes
Transition Mode & Active Tracking Boost Function.
Maximum Operating Temperature
+ 60 C
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
L6563S
Other names
497-10488

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EVL6563S-400W
Manufacturer:
ST
0
Test results and significant waveforms
2
2.1
8/38
Figure 3.
Figure 5.
 
 
0.0001
0.001
0.0001
0.01
0.001
0.1
0.01
0.1
1
10
1
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Measured value
Test results and significant waveforms
Harmonic content measurement
One of the main purposes of a PFC pre-conditioner is to correct the input current distortion,
decreasing the harmonic contents below the limits of the relevant regulations. Therefore, the
board has been tested according to the European rule EN61000-3-2 Class-D and Japanese
rule JEITA-MITI Class-D, at full load and 70 W output power, at both the nominal input
voltage mains.
As shown in the following figures, the circuit can reduce the harmonics well below the limits
of both regulations from full load down to light load. An output power of 70 W has been
chosen because it is almost the lower power limit at which the harmonics have to be limited
according the mentioned rules.
Measured value
EVL6563S-400W compliance to
EN61000-3-2 Standard at full load
EVL6563S-400W compliance to
EN61000-3-2 Standard at 70 W load
Harmon ic Or der [n]
Harmonic Order [n]
EN61000-3-2 Class-D limits
EN61000-3-2 Class-D limits
Doc ID 15796 Rev 2
Figure 4.
Figure 6.
 
 
0.0001
0.001
0.0001
0.01
0.001
0.1
10
0.01
1
0.1
1
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
EVL6563S-400W compliance to
JEITA-MITI Standard at full load
EVL6563S-400W compliance to
JEITA-MITI Standard at 70 W load
Measured value
Measur ed value
Harmonic Ord er [n]
H armo nic O rder [n]
JEITA-MITI limits
JEIT A -MITI limits
AN2994