STEVAL-ISB005V1 STMicroelectronics, STEVAL-ISB005V1 Datasheet - Page 135

BOARD EVAL CHARGER ST7260/L6924D

STEVAL-ISB005V1

Manufacturer Part Number
STEVAL-ISB005V1
Description
BOARD EVAL CHARGER ST7260/L6924D
Manufacturer
STMicroelectronics
Type
Battery Managementr
Datasheets

Specifications of STEVAL-ISB005V1

Main Purpose
Power Management, Battery Charger
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
L6924, ST72F63BK6M1
Primary Attributes
1 Cell- Li-Ion / Li-Pol, 5 V (USB Input)
Secondary Attributes
Powered by Wall Adaptor Also, LED Status Indicators
Input Voltage
5 V
Product
Power Management Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
L6924D, ST7260
Other names
497-8428

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STEVAL-ISB005V1
Manufacturer:
STMicroelectronics
Quantity:
1
ST7260xx
19
19.1
19.2
19.3
Known limitations
PA2 limitation with OCMP1 enabled
Description
This limitation affects only Rev B Flash devices (with Internal Sales Type 72F60xxxxx$x7); it
has been corrected in Rev W Flash devices (with Internal Sales Type 72F60xxxxx$x9).
Refer to
When Output Compare 1 function (OCMP1) on pin PA6 is enabled by setting the OC1E bit in
the TCR2 register, pin PA2 is also affected.
In particular, the PA2 pin is forced to be floating even if port configuration (PADDR+PADR)
has set it as output low. However, it can be still used as an input.
Unexpected reset fetch
If an interrupt request occurs while a "POP CC" instruction is executed, the interrupt
controller does not recognise the source of the interrupt and, by default, passes the RESET
vector address to the CPU.
Workaround
To solve this issue, a "POP CC" instruction must always be preceded by a "SIM" instruction.
SCI wrong break duration
Description
A single break character is sent by setting and resetting the SBK bit in the SCICR2 register.
In some cases, the break character may have a longer duration than expected:
In the same way, as long as the SBK bit is set, break characters are sent to the TDO pin.
This may lead to generate one break more than expected.
Occurrence
The occurrence of the problem is random and proportional to the baudrate. With a transmit
frequency of 19200 baud (f
occurrence is around 1%.
Workaround
If this wrong duration is not compliant with the communication protocol in the application,
software can request that an Idle line be generated before the break character. In this case,
the break duration is always correct assuming the application is not doing anything between
the idle and the break. This can be ensured by temporarily disabling interrupts.
20 bits instead of 10 bits if M=0
22 bits instead of 11 bits if M=1
Figure 69 on page
CPU
137.
=8 MHz and SCIBRR=0xC9), the wrong break duration
Known limitations
135/139