Main Purpose
Power Management, Triac Controller
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
STCC08, ST7FLITE39F2
Primary Attributes
AC Switch Driver with Failure Mode Detector
Secondary Attributes
4 Toggle Switches for Failure Simulation, Capacitive Power Supply
Input Voltage
5 V
Product
Power Management Modules
Silicon Manufacturer
ST Micro
Silicon Core Number
STCC08
Kit Application Type
Power Management
Application Sub Type
AC Switch Failure Mode Detector
Kit Contents
Board Docs
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
ST7LITE39F2
Other names
497-8403

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STEVAL-IHM020V1
Manufacturer:
ST
0
Using the demonstration board
14/23
To operate the STCC08 board correctly and at each test, perform the following
procedure first:
To turn on the AC switch:
To simulate a diode mode of the ACS:
To simulate a short-circuit of the ACS:
To simulate an open circuit of the ACS:
To simulate AC switch failures in any AC load state:
Read the “AVF” test point (TP8) with an oscilloscope connected through an insulated
plug (see example in
Place the “STCC08 CNTRL” switch (SW5) to the “OFF” position
Set the “N DIODE MODE (SW2)” and “P DIODE MODE (SW3)” switches to the
“NO” position
Put the “OPEN LOAD” (SW1) switch in the “NO” position
Set the “OPEN ACS” (SW4) switch to the “NO” position
Connect the AC mains wire to the AC line connector (J1).
In this case, all LEDs must be off
Place all mechanical switches (SW1, SW2, SW3 and SW4) in the “NO” position
Put the “STCC08 CNTRL” switch (SW5) in the “ON” position
The “STCC08 CNTRL” LED (D5) and the “ON” LED (D9) must be on
The light bulb must be on
Set the “N DIODE MODE” (SW2) or “P DIODE MODE” (SW3) switch to the “YES”
position, SW1and SW4 to the “NO” position and SW5 to the “OFF” position
In this case, the “DIODE” (D6) LED is on
Put the “N DIODE MODE” (SW2) and “P DIODE MODE” (SW3) switches in the
“YES” position, SW1and SW4 in the “NO” position and SW5 in the “OFF” position
In this case, the “CC” LED (D8) is on
Place the “STCC08 CNTRL” switch (SW5) in the “ON” position and all mechanical
switches (SW1, SW2, SW3 and SW4) in the “NO” position
Put the “OPEN ACS” (SW4) switch in the “ON” position
In this case, the “OPEN” LED (D7) and “STCC08 CNTRL” LED (D9) is on
Place the “OPEN LOAD” (SW1) switch in the “YES” position (this disconnects the
AC load) and use the previous procedures to see the AC switch (ACS) state is
detected whatever the AC load state (AC load connected or disconnected)
Figure
9,
10
and 11).