DEMOBOARD TLE 6244X Infineon Technologies, DEMOBOARD TLE 6244X Datasheet - Page 28

BOARD DEMO FOR TLE 6244X

DEMOBOARD TLE 6244X

Manufacturer Part Number
DEMOBOARD TLE 6244X
Description
BOARD DEMO FOR TLE 6244X
Manufacturer
Infineon Technologies
Datasheet

Specifications of DEMOBOARD TLE 6244X

Main Purpose
Power Management, Low Side Driver (Internal FET)
Embedded
No
Utilized Ic / Part
TLE6244
Primary Attributes
18 Channel Internal Switch
Secondary Attributes
Overvoltage, Short-Circuit & Thermal Protection
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
DEMOBOARDTLE6244XIN
Final Data Sheet
Reading the State resp. the Configuration:
(SPI Instructions: WR_STATCON, RD_STATCON)
CONFIG2
Register:
Bit
7
0
1
2
3
4
5
CONFIG1
Name
STATUS0
STATUS1
STATUS2
STATUS3
STATUS4
CONFIG0
STATCON_REG
6
CONFIG0
5
Overvoltage information (bit STATUS0 = 0) will not be reset by an
external reset signal (pin RST=low). Overvoltage will be detected
and stored (CONFIG0 = 1) during RST=low. The information will be
deleted when an internal (undervoltage) reset occurs or when
CONFIG0 is set to 0.
Description
Bit = 1: No overvoltage at VDD
Bit = 0: Overvoltage at VDD resp. state of overvoltage still
Access by Controller:
Bit = 1: No undervoltage at VDD
Bit = 0: Undervoltage at VDD
Access by Controller:
Reading the voltage level at ABE
Access by Controller:
Common error flag
Bit =1: At present no error is entered in one of the 5 diag-
Bit = 0: For at least at one power stage an error has been
Access by Controller:
Common overtemperature flag
Bit = 1: No overtemperature detected since the last reset
Bit = 0: Overtemperature for at least one power stage has
State of Reset: 1
Access by Controller:
Bit = 1: Latch function for overvoltage at VDD is switched on
Bit = 0: Latch function for overvoltage at VDD is switched off
State of Reset: 1
Access by Controller:
STATUS4
4
detected and entered in the corresponding diagnostic
nostic registers DIA_REG1..5.
register.
stored (reset by CONFIG0 = 0)
of diagnostic information (by del_dia instruction,
RST = Low or undervoltage at VDD (see 3.2. ))
been detected since the last reset of the
diagnostic information (by del_dia instruction,
RST = Low or undervoltage at VDD (see 3.2. ))
28
STATUS3
3
STATUS2
Read only
Read only
Read only
Read only
Read only
Read/Write
2
STATUS1
1
TLE 6244X
V4.2, 2003-08-29
STATUS0
0