ATQT600 Atmel, ATQT600 Datasheet - Page 133

KIT EVAL TOUCH FOR QT600

ATQT600

Manufacturer Part Number
ATQT600
Description
KIT EVAL TOUCH FOR QT600
Manufacturer
Atmel
Series
QTouch™r
Datasheets

Specifications of ATQT600

Sensor Type
Touch Screen
Interface
USB
Embedded
Yes, Other
Utilized Ic / Part
ATtiny88, ATmega324PA, ATxmega128A1
Processor To Be Evaluated
ATtiny88, ATmega324, ATxmega128
Data Bus Width
8 bit, 16 bit
Interface Type
USB
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
1.6 V to 3.6 V
Silicon Manufacturer
Atmel
Kit Application Type
Sensor
Application Sub Type
Touch Sensor
Kit Contents
USB Bridge, MCU Cards, Touchpad Cards
Svhc
No SVHC (15-Dec-2010)
Mcu Supported Families
ATtiny88,
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Sensitivity
-
Sensing Range
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATQT600
Manufacturer:
Atmel
Quantity:
135
Values
RAW_ACQ_MODE
NORMAL_ACQ_MODE
6.3.15.2.4 sensor_type_t
Enumeration
Use
Values
SENSOR_TYPE_UNASSIGNED
SENSOR_TYPE_KEY
SENSOR_TYPE_ROTOR
SENSOR_TYPE_SLIDER
6.3.15.2.5 aks_group_t
Enumeration
Use
Values
NO_AKS_GROUP
AKS_GROUP_1
AKS_GROUP_2
AKS_GROUP_3
AKS_GROUP_4
AKS_GROUP_5
AKS_GROUP_6
AKS_GROUP_7
6.3.15.2.6 hysteresis_t
Enumeration
Use
Hysteresis_t
Defines the sensor detection hysteresis value. This is expressed as a
percentage of the sensor detection threshold.
This is configurable per sensor.
HYST_x = hysteresis value is x percent of detection threshold value (rounded
down).
Note that a minimum value of 2 is used as a hard limit. Example: if detection
threshold = 20, then:
HYST_50 = 10 (50 percent of 20)
HYST_25 = 5 (25 percent of 20)
sensor_type_t
Define the type of the sensor
aks_group_t
Defines the Adjacent Key Suppression (AKS) groups that each sensor may be
associated with
AKS™ is selectable by the system designer
7 AKS groups are supported by the library
Comment
When Raw acquisition mode is used, the measure_complete_callback
function is called immediately once fresh values of Signals are
available. In this mode, the Touch Library does not do any processing
on the Signals.
position values are not updated in this mode.
When
measure_complete_callback function is called only after the Touch
Library completes processing of the Signal values obtained. The
References, Sensor states and Rotor/Slider position values are
updated in this mode.
Comment
No AKS group is selected for the sensor
AKS Group number 1
AKS Group number 2
AKS Group number 3
AKS Group number 4
AKS Group number 5
AKS Group number 6
AKS Group number 7
Nomal
So, the references, Sensor states or Rotor/Slider
Comment
Channel is not assigned to any sensor
Sensor is a key
Sensor is a rotor
Sensor is a slider
acquisition
mode
is
used,
133
the

Related parts for ATQT600