ATQT600 Atmel, ATQT600 Datasheet - Page 44

KIT EVAL TOUCH FOR QT600

ATQT600

Manufacturer Part Number
ATQT600
Description
KIT EVAL TOUCH FOR QT600
Manufacturer
Atmel
Series
QTouch™r
Datasheets

Specifications of ATQT600

Sensor Type
Touch Screen
Interface
USB
Embedded
Yes, Other
Utilized Ic / Part
ATtiny88, ATmega324PA, ATxmega128A1
Processor To Be Evaluated
ATtiny88, ATmega324, ATxmega128
Data Bus Width
8 bit, 16 bit
Interface Type
USB
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
1.6 V to 3.6 V
Silicon Manufacturer
Atmel
Kit Application Type
Sensor
Application Sub Type
Touch Sensor
Kit Contents
USB Bridge, MCU Cards, Touchpad Cards
Svhc
No SVHC (15-Dec-2010)
Mcu Supported Families
ATtiny88,
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Sensitivity
-
Sensing Range
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATQT600
Manufacturer:
Atmel
Quantity:
135
Note: The above constraints are explained with respect to 8bit AVR. The same could be extended
to 32bit AVR and ATSAM for 32 channel libraries where each port has 32 pins.
5.6.7.2
QMatrix acquisition method libraries are available for a set of AVRs The library variants can be
configured to have port and pin assignments for X, Ya, Yb and SMP. Please refer to section 5.8.2
for port-pin configurability.
Some of the key constraints are
44
If two port pairs are used for the design, all the channels for a sensor have to be
connected on a single port pair. Combining channels from multiple ports is not possible
when designing sensors. e.g. It is not possible to have a rotor with channel numbers (
7,8,9 ) on a 16 channel library variant which uses two port-pairs.
The QMatrix acquisition method libraries internally use TIMER1 for the operation,
TIMER1 will not be available for critical sections of the code where the library is called.
But resources are available to the host application when the normal user’s application is
running.
In case of XMEGA™ devices, the resources are used internal to the library and hence
cannot be used by the host application
The sensor channel number and the relation with X and Y lines strictly follows from the
table provided in the section Table 1.
A rotor /slider sensor can be configured with 3 to 8 channels per rotor or slider depending
on the requirement of the application subject to the total number of channels available in
the library variant selected as listed below.
For example, 16 channel libraries with 4X and 4Y lines supports maximum of 4 channels
per Rotor/Slider. But, a 16 channel with 8X and 2Y lines supports maximum of 8
channels per Rotor/Slider.
If the lines of the Drive and Receive electrode (X lines or the Y lines) share the same
lines with the JTAG, JTAG needs to be disabled. Please check the data sheet to ensure
that there are no conflicts between the X/Y lines and JTAG lines used for the device.
YB line for a particular device cannot be changed and it has to be the configured to be
the ADC port of the selected device.
The AIN0 pin of the device needs to be connected to the GND.
In case of XMEGA devices, the reference pin for input to analog comparator is Pin7 of
PORTA with all the combinations of libraries supported. Hence, this needs to be
connected to GND
Proper grounding should be taken care when the controller board and touch sensing
board are different.
QMatrix acquisition method constraints
o
o
o
Timer/Counter 1 on PORTC (TCC1)
Analog Comparator on PORTA (ACA)
Event System Channel0 (EVSYS_CH0)
Number of
channels
16
16
32
56
64
4
8
X x Y
4 x 1
4 x 2
4 x 4
8 x 2
8 x 4
8 x 7
8 x 8
Maximum Channels per ROTOR_SLIDER
4
4
4
8
8
8
8
8207J-AT42-02/11