ATQT600 Atmel, ATQT600 Datasheet - Page 30

KIT EVAL TOUCH FOR QT600

ATQT600

Manufacturer Part Number
ATQT600
Description
KIT EVAL TOUCH FOR QT600
Manufacturer
Atmel
Series
QTouch™r
Datasheets

Specifications of ATQT600

Sensor Type
Touch Screen
Interface
USB
Embedded
Yes, Other
Utilized Ic / Part
ATtiny88, ATmega324PA, ATxmega128A1
Processor To Be Evaluated
ATtiny88, ATmega324, ATxmega128
Data Bus Width
8 bit, 16 bit
Interface Type
USB
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
1.6 V to 3.6 V
Silicon Manufacturer
Atmel
Kit Application Type
Sensor
Application Sub Type
Touch Sensor
Kit Contents
USB Bridge, MCU Cards, Touchpad Cards
Svhc
No SVHC (15-Dec-2010)
Mcu Supported Families
ATtiny88,
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Sensitivity
-
Sensing Range
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATQT600
Manufacturer:
Atmel
Quantity:
135
NOTE:
5.6.5.6
This function performs a capacitive measurement on all enabled sensors. The measured signals
for each sensor are then processed to check for user touches, releases, changes in rotor angle
and changes in slider position.
unit16_t qt_measure_sensors( uint16_t current_time_ms
Arguments
current_time_ms
Return
Value
uint16_t
NOTE:
5.6.5.7
This function forces a recalibration of all enabled sensors.
30
All
qt_enable_slider ) before calling this function.
This functions initializes all the configured sensors, performs calibration.
All sensors must be configured (using qt_enable_key or qt_enable_rotor or
qt_enable_slider) and initialized by calling qt_init_sensing before calling this function.
Comment
Returns the status of the Library as a combination of the following bit fields.
Return value
QTLIB_NO_ACTIVITY
QTLIB_IN_DETECT
QTLIB_STATUS_CHANGE
QTLIB_ROTOR_SLIDER_POS_CHANGE
QTLIB_CHANNEL_REF_CHANGE
QTLIB_BURST_AGAIN
QTLIB_RESOLVE_CAL
QTLIB_RESOLVE_FILTERIN
QTLIB_RESOLVE_DI
QTLIB_RESOLVE_POS_RECAL
qt_measure_sensors
qt_calibrate_sensing
sensors
Type
uint16
must
Comment
The current time in milliseconds
be
configured
(using
Bit
definition
0x0000
0x0001
0x0002
0x0004
0x0008
0x0100
0x0200
0x0400
0x0800
0x1000
qt_enable_key,
At least one rotor/slider has changed
At least one reference value has
Comments
No activity detected on any of the
sensors
At least one sensor is in detect
At least one sensor has changed
ON/OFF state since the last call to
qt_measure_sensor()
position
qt_measure_sensors()
changed
qt_measure_sensors()
Flag to indicate Multiple measurements
needed.
Multiple
resolve
qt_measure_sensors( ) once again.
Multiple
resolve
qt_measure_sensors( ) once again.
Multiple
resolve
qt_measure_sensors( ) once again.
Multiple
resolve
qt_measure_sensors( ) once again.
positive
measurements
measurements
measurements
measurements
since
detect
since
)
8207J-AT42-02/11
calibration.
qt_enable_rotor
filtering.
the
recalibration.
integration.
last
last
needed
needed
needed
needed
call
call
Call
Call
Call
Call
or
to
to
to
to
to
to

Related parts for ATQT600