CYIL1SM4000-EVAL Cypress Semiconductor Corp, CYIL1SM4000-EVAL Datasheet - Page 48

BOARD EVAL IMAGE SENS LUPA-4000

CYIL1SM4000-EVAL

Manufacturer Part Number
CYIL1SM4000-EVAL
Description
BOARD EVAL IMAGE SENS LUPA-4000
Manufacturer
Cypress Semiconductor Corp
Datasheets

Specifications of CYIL1SM4000-EVAL

Sensor Type
CMOS Imaging, Monochrome
Sensing Range
4 Megapixel
Interface
SPI
Sensitivity
15 fps
Voltage - Supply
2.5 V ~ 3.3 V
Embedded
No
Utilized Ic / Part
LUPA-4000
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
APPENDIX B:
Q:
A:
The green lines are the analog signal on the photodiode, which decrease as a result of
exposure. The slope is determined by the amount of light at each pixel (the more light
the steeper the slope). When the pixels reach the saturation level the analog signal will
not change despite further exposure. As you can see without any double slope pulse
pixels p3 and p4 will reach saturation before the sample moment of the analog values,
no signal will be acquired without double slope. When double slope is enabled a
second reset pulse will be given (blue line) at a certain time before the end of the
integration time. This double slope reset pulse resets the analog signal of the pixels
BELOW this level to the reset level. After the reset the analog signal starts to decrease
with the same slope as before the double slope reset pulse. If the double slope reset
pulse is placed at the end of the integration time (90% for instance) the analog signal
that would have reach the saturation levels aren't saturated anymore (this increases the
optical dynamic range) at read out. It's important to notice that pixel signals above
the double slope reset level will not be influenced by this double slope reset pulse (p1
and p2).
Contact:
Cypress Semiconductor Corporation
LUPA-4000
Data Sheet
Reset pulse
How does the dual (multiple) slope extended dynamic range mode works?
info@Fillfactory.com
Total integration time
Double slope reset pulse
Document #: 38-05712 Rev.**(Revision 1.2 )
Frequently Asked Questions
Figure 27: Dual slope diagram
3901 North First Street
Read out
p1
p4
p2
p3
Double slope reset time (usually 5-
10% of the total integration time)
San Jose, CA 95134
Reset level 1
Reset level 2
Saturation level
Page 48 of 49
408-943-2600