Specifications of M3062PT-EPB

Accessory Type
Probe Accessory Kit
For Use With/related Products
PC7501, M16C/62
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Note on Protect Register:
Notes on Pullup Control:
Note on Operating Frequency:
Notes on Internal Flash ROM of the MCU:
• The protect is not canceled when bit 2 of protect register PRCR (PRC2), which enables writing into
• Because this product emulates some I/O ports (P0 to P5, P10), you can not pullup ports P0 to P5
• The initial value of pullup control register 1 PUR1 of this product is different from that of an actual
• You can not use this product with a main clock (X
• This product downloads a user program to the flash ROM in an MCU when debugging in single-
• Because the number of write/erase cycles of the internal flash ROM of the MCU is limited, it must
• If the following errors occur frequently when downloading a program, replace the MCU board.
To purchase products for replacement, contact your local distributor.
the port P9 direction register and the SI/Oi control register, is changed with the below procedure.
by the pullup control registers. Install the included resistor arrays (51 kΩ) as necessary.
MCU. When a Vcc level is input to pin CNVss, the value of an actual MCU is "02h" (bit 1 PU11
is "1"), while that of this product is "00h".
clock less than 1 MHz, contact your local distributor.
chip or memory expansion mode. By checking "Disable the Internal Flash ROM" in the MCU tab
of the MCU setting dialog box of the emulator debugger, you can disable the operation of the
internal flash ROM of the MCU to use the emulation memory. However, the maximum operating
frequency is 10 MHz.
be replaced at the end of its service-life.
(1) Step execution of an instruction setting PRC2 to "1"
(2) Setting a break point between an instruction setting PRC2 to "1" and a point where the port
(3) Setting PRC2 to "1" by the memory window or script window
(1) Flash ROM erase error occurred ERROR (16258)
(2) Flash ROM verify error occurred ERROR (16259)
P9 direction register or the SI/Oi control register is set
IMPORTANT