19. Note on [Registers] Window Operation During Program Execution
20. Note on Radix in the [Register] Dialog Box
21. BREAKPOINT
22. Number of BREAKPOINT and [Stop At] Settings in the [Run...] Menu
23. Note on RUN-TIME Display
Although a dialog box is displayed in which the register contents can be changed by double-
clicking the [Registers] window, do not change the register contents during program
execution.
The default input radix in the [Register] dialog box is hexadecimal irrespective of the Radix
display. When a radix other than a hexadecimal is input, specify the prefix code such as B'.
After the value has been input in the [Register] dialog box, the Radix setting is changed to
hexadecimal. When the radix other than a hexadecimal is used as a default, reset the Radix
display.
The maximum number of BREAKPOINTs and [Stop At] settings allowed in the [Run...] menu
is 255. Therefore, when 255 BREAKPOINTs are set, specification by [Stop At] in the [Run...]
menu becomes invalid. Use the BREAKPOINTs and [Stop At] in the [Run...] menu with 255
or less total settings.
The execution time of the user program displayed in the [Status] window may not be accurate
since the timer in the host computer is used.
Session file
When the BREAKPOINT address set in the session file is H'0, the breakpoint will not be
set. If the address set as the breakpoint is wrong, the error message is not output. The
breakpoint is registered as DISABLE in the [Breakpoints] window.
Breakpoint cancellation
When the contents of the BREAKPOINT address is modified during user program
execution, the following message is displayed when the user program stops.
If the above message is displayed, cancel all BREAKPOINT settings with the [Delete All]
or [Disable] button in the [Breakpoints] window.
[Run program] dialog box
If a disabled BREAKPOINT address is specified as a stop address in the [Run Program]
dialog box, the disabled BREAKPOINT will become enabled after the user program has
stopped.
[Breakpoints] window
During user program execution, it is impossible to jump from the breakpoint to the source
or address line on the [Source] or [Disassembly] window by using [Go to Source] in the
popup menu displayed on the [Breakpoints] window.
BREAKPOINT IS DELETED A=xxxxxxxx
209