Y92S-38 Omron, Y92S-38 Datasheet - Page 32

LOCK KEY PEN FOR H3DS RELAYS

Y92S-38

Manufacturer Part Number
Y92S-38
Description
LOCK KEY PEN FOR H3DS RELAYS
Manufacturer
Omron
Series
H3DSr
Datasheets

Specifications of Y92S-38

Accessory Type
Tool - Lock Key Pen
For Use With/related Products
H3DS Series
For Use With
H3DS-SLCAC24-230/DC24 - TIMER CAGE CLAMP 17.5MM 4MODESH3DS-MLCAC24-230/DC24-48 - TIMER CAGE CLAMP 17.5MM 8MODESZ2395 - RELAY TIME DELAY 4MODE DIN MNTZ2394 - RELAY TIME DELAY 1MODE DIN MNTZ2393 - RELAY TIME DELAY 8MODE DIN MNTZ2392 - RELAY TIME DELAY 1MODE DIN MNT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92S38
Z2396
H3DS-G
I
I
Setting of Selector
The selectors can be turned clockwise and counterclockwise to
select the desired time scale, or operating mode.
Each selector has a snap mechanism that secures the selector at
a given position. Set the selector at a position at which it is
secured. Do not set it midway between two securing positions or a
malfunction could result from improper setting.
Selection of Time Unit and Time Scale
The star-delta transfer time and star operation time scale are set
with the same selector. The star-delta transfer time can be set to
0.05, 0.1, 0.5, or 1. The star operation time scale can be set to a
multiplication factor of 1 or 10. If the star-delta transfer time is dis-
played in the display window in white letters, this means that the
star operation time scale is “x10”. Refer to the example below.
I
Note: The reset time requires a maximum of 0.5 s.
Inputs
Outputs
I/O Functions
Basic Operation
Timing Charts
Star-delta transfer time
Star-delta transfer time and
star operation time scale
display window and selector
0.05 s
0.05 s
0.1 s
0.5 s
0.1 s
0.5 s
1 s
1 s
Power (A
Star contact
17 and 18
(star indicator)
Delta contact
27 and 28
(delta indicator)
1
Control output
and A
2
)
ON
OFF
ON
OFF
ON
OFF
Star operation time scale
t
t
1
2
: Star operation time setting
: Star-delta transfer time
t
1
x10
x1
Star output is turned OFF when the dial set value is reached and delta output is ON
---
after the preset transfer time elapses
t
2
0.5 s
Time Setting
The star operation time of the Timer is set with the time setting
dial.
Locking/Unlocking of Selectors and Time Setting Dial
The time setting dial and time scale selector can be locked using
the Y92S-38 Lock Key, a special pen type tool that is sold sepa-
rately. To lock the dial or selectors, insert the Lock Key in the key-
hole to the lower right of the dial or selector and turn it clockwise
until the dial or selector is completely covered with the red cover.
To unlock, turn the Lock Key in the opposite direction.
Key hole
H3DS-G

Related parts for Y92S-38