P2CF-11-E Omron, P2CF-11-E Datasheet - Page 4

no-image

P2CF-11-E

Manufacturer Part Number
P2CF-11-E
Description
SOCKET 11-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr
Series
-r
Datasheets

Specifications of P2CF-11-E

Number Of Positions
11
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Features
-
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
11
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
For Use With/related Products
Multiple Series
For Use With
Z2998 - RELAY TIMER DGTL SPDT 100/240VACZ2366 - RELAY REPEAT CYCLE ANLG 30HRSZ997 - RELAY TIMER ANALOG 24VDC/ACZ2358 - RELAY REPEAT CYCLE ANLG 30HRSZ876 - RELAY TIMER DPDT ANALOG 120\240V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF11E
4
E5CN/E5CN-U
Lineup
Note: Models with one control output and one or two auxiliary outputs and models with two control outputs can be used for heating/cooling control.
Model Number Structure
Model Number Legend
Controllers
1. Control Output 1
2. Auxiliary Outputs ✽2
3. Option
4. Input Type
5. Power Supply Voltage
6. Case Color
7. Terminal Cover
Note: Not all combinations of function 1 and function 2 specifications are possible for Option Units (E53-@@@@).
✽1. Always connect an AC load to a long-life relay output. The output will not turn OFF if a DC load is connected because a triac is used for
✽2. Auxiliary outputs are contact outputs that can be used to output alarms or results of logic operations.
E5CN-@@M@@-@-500
R: Relay output
Q: Voltage output (for driving SSR)
C: Current output
Y: Long-life relay output (hybrid) ✽1
Blank: None
2: Two outputs
M: Option Unit can be mounted.
T: Universal thermocouple/platinum resistance thermometer
L: Analog current/voltage input
Blank: 100 to 240 VAC
D: 24 VAC/VDC
Blank: Black
W: Silver
-500: With terminal cover
E5CN
Basic Type
switching the circuit. For details, check the conditions in Ratings.
1 2 3 4 5
6
7
Terminal block
Plug-in
Temperature input
Temperature input
Analog input
Analog input
Option Units
1. Applicable Controller
2. Function 1
3. Function 2
4. Version
E53-CN@@@
CN: E5CN or E5CN-H
Blank: None
Q: Control output 2 (voltage for driving SSR)
P: Power supply for sensor
Blank: None
H: Heater burnout/SSR failure/Heater overcurrent detection (CT1)
HH: Heater burnout/SSR failure/Heater overcurrent detection
B: Two event inputs
03: RS-485 communications
H03: Heater burnout/SSR failure/Heater overcurrent detection
HB: Heater burnout/SSR failure/Heater overcurrent detection
HH03: Heater burnout/SSR failure/Heater overcurrent detection
N2: Applicable only to models released after January 2008
(CT2)
(CT1) + Two event inputs
(CT1) + RS-485 communications
1
(CT2) + RS-485 communications
2 3 4
2 control outputs
2 control outputs
1 control output
1 control output
1 control output
1 control output
0 or 2 auxiliary outputs
2 auxiliary outputs
0 or 2 auxiliary outputs
2 auxiliary outputs
0, 1, or 2 auxiliary
outputs
0, 1, or 2 auxiliary
outputs

Related parts for P2CF-11-E