P2CF-11-E Omron, P2CF-11-E Datasheet - Page 49

no-image

P2CF-11-E

Manufacturer Part Number
P2CF-11-E
Description
SOCKET 11-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr
Series
-r
Datasheets

Specifications of P2CF-11-E

Number Of Positions
11
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Features
-
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
11
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
For Use With/related Products
Multiple Series
For Use With
Z2998 - RELAY TIMER DGTL SPDT 100/240VACZ2366 - RELAY REPEAT CYCLE ANLG 30HRSZ997 - RELAY TIMER ANALOG 24VDC/ACZ2358 - RELAY REPEAT CYCLE ANLG 30HRSZ876 - RELAY TIMER DPDT ANALOG 120\240V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF11E
Alarm Outputs
Each alarm can be independently set to one of the following 15 alarm types. The default is 2: Upper limit.
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm 1 will be an OR output of the alarm selected from the
val-
Set
ue
10
11
12
13
14
✽1
✽1
✽1
15
0
1
2
3
4
5
6
7
8
9
following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To output only a heater burnout alarm, SSR
failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function).
Alarm function
OFF
Upper- and lower-
limit
Upper limit
Lower limit
Upper- and lower-
limit range
Upper- and lower-
limit with standby
sequence
Upper-limit with
standby
sequence
Lower-limit with
standby
sequence
Absolute-value
upper-limit
Absolute-value
lower-limit
Absolute-value
upper-limit with
standby
sequence
Absolute-value
lower-limit with
standby
sequence
LBA (for alarm 1
only)
PV change rate
alarm
RSP absolute
value upper limit
✽6
RSP absolute
value lower limit
✽6
Alarm type
✽5
Output OFF
---
---
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
When X is
positive
Alarm output operation
0
0
0
0
0
0
L
X
L
L
X
SP
SP
SP
SP
SP
SP
SP
X
X
X
X
X
X
H
H
H
X
X
✽2
✽3
✽4
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
When X is
negative
X
X
SP
SP
SP
SP
X
X
X
X
X
X
X
X
0
0
0
0
0
0
✽1.With set values 1, 4 and 5, the upper and lower limit values can be
✽2. Set value: 1, Upper- and lower-limit alarm
✽3. Set value: 4, Upper- and lower-limit range
✽4. Set value: 5, Upper- and lower-limit with standby sequence
✽5. Set value: 5, Upper- and lower-limit with standby sequence
✽6. Displayed when there is a remote SP input.
set independently for each alarm type, and are expressed as “L”
and “H.”
For Upper- and Lower-Limit Alarm Described Above
Always OFF when the upper-limit and lower-limit hysteresis
overlaps.
• Case 1 and 2
• Case 3: Always OFF
Always OFF when the upper-limit and lower-limit hysteresis
overlaps.
Case 1
Case 1
H < 0, L > 0
H < 0, L > 0
H < L
H < L
L
L
H
H
SP
SP
Case 2
Case 2
SP
SP
H > 0, L < 0
H > 0, L < 0
H > L
H > L
L H
L H
E5AN-H/E5EN-H
Case 3 (Always ON)
Case 3 (Always ON)
H
H
H
H
L
L
SP
SP
SP
SP
SP
SP
H
H
L
L
L
L
H < 0, L > 0
H > 0, L < 0
H < 0, L > 0
H > 0, L < 0
H < 0, L < 0
H < 0, L < 0
H
H
H
H
L
L
L
L
49

Related parts for P2CF-11-E