P2CF-11-E Omron, P2CF-11-E Datasheet - Page 53

no-image

P2CF-11-E

Manufacturer Part Number
P2CF-11-E
Description
SOCKET 11-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr
Series
-r
Datasheets

Specifications of P2CF-11-E

Number Of Positions
11
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Features
-
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
11
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
For Use With/related Products
Multiple Series
For Use With
Z2998 - RELAY TIMER DGTL SPDT 100/240VACZ2366 - RELAY REPEAT CYCLE ANLG 30HRSZ997 - RELAY TIMER ANALOG 24VDC/ACZ2358 - RELAY REPEAT CYCLE ANLG 30HRSZ876 - RELAY TIMER DPDT ANALOG 120\240V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF11E
External Connections
Note: Wire all voltage input terminals correctly. The Controller may fail if voltage input terminals are wired incorrectly.
Controllers
Output Unit
Control outputs 1, 2
Relay Outputs
250 VAC, 5 A
(resistive load)
SSR Outputs
75 to 250 VAC, 1A
(resistive load)
Models with Position-
proportional Control
250 VAC, 1 A
(including inrush
current)
Relay output
SPST-NO,
250 VAC, 3 A
(resistive load)
100 to 240 VAC
24 VAC/VDC (no polarity)
A voltage output (control output 1, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple,
do not connect any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the
measured temperature values as a result of leakage current.
The voltage output (control output 2, for driving SSR) has basic insulation provided for the internal circuit
Control outputs 1, 2
Auxiliary outputs 1, 2
Input power
supply
Control output 2
Auxiliary output 2
Auxiliary output 1
Control output 1
DO NOT USE
Remote SP input
Transfer output
EV3
10
1
2
3
4
5
6
7
8
9
EV4
21
21
22
22
23
23
24
24
25
25
26
26
27
27
28
28
29
29
30
30
21
22
23
24
25
26
27
28
29
30
4 to 20 mA DC
(Load: 600
4 to 20 mA DC
11
12
13
14
15
16
17
18
19
20
DO NOT
USE
DO NOT
USE
CT2
Event Inputs
EV2
Option Units
max.)
CT1
CT2
11
12
13
21
22
E53-EN01
RS-232C
EV1
DO NOT
USE
Potentiometer
SD
RD
SG
DO NOT USE
DO NOT USE
W
A
B
B
O
C
DO NOT
USE
DO NOT
USE
14
15
16
11
12
13
21
22
E53-EN02
RS-422
V
Auxiliary output 3
DO NOT
USE
DO NOT
USE
RDB
RDA
SG
SDB
SDA
Communications
mA
E53-EN03
RS-485
11
12
13
21
22
E5AN-H/E5EN-H
A heater burnout alarm, SSR
failure, heater overcurrent
alarm, or input alarm is sent
to the output to which the
alarm 1 function is assigned.
Relay output
SPDT, 250 VAC, 3 A
(resistive load)
B ( )
A ( )
DO NOT USE
B ( )
A ( )
Auxiliary output 3
11
12
13
21
22
E53-AKB
Event Inputs
EV2
EV1
53