SLRC40001T/OFE,112 NXP Semiconductors, SLRC40001T/OFE,112 Datasheet - Page 64

IC I.CODE SLRC400 READER 32-SOIC

SLRC40001T/OFE,112

Manufacturer Part Number
SLRC40001T/OFE,112
Description
IC I.CODE SLRC400 READER 32-SOIC
Manufacturer
NXP Semiconductors
Series
I-Coder

Specifications of SLRC40001T/OFE,112

Rf Type
Read Only
Frequency
13.56MHz
Features
ISO15693, ISO18000-3
Package / Case
32-SOIC (0.300", 7.50mm Width)
Product
RFID Readers
Operating Temperature Range
- 25 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-1124-5
935269551112
SLRC400
SLRC41TOFED
Philips Semiconductors
I•CODE Reader IC
PRODUCT SERIAL NUMBER
The SL RC400 holds a four byte serial number that is unique for each device.
INTERNAL:
These 2 bytes hold internal trimming parameters.
MAXIMUM SOURCE RESISTANCE FOR THE P-CHANNEL DRIVER TRANSISTOR OF PIN TX1 AND TX2
The source resistance of the p-channel driver transistors of pin TX1 and TX2 may be adjusted via the
GsConfCW Register (see chapter 13.2.1). The mean value of the maximum adjustable source resistance of
the pins TX1 and TX2 is stored as an integer value in Ohms in byte RsMaxP.
This value is denoted as maximum adjustable source resistance Rs
Register set to 01
CRC
The content of the product information field is secured via a CRC-byte, which is checked during start up.
6.3
Register initialisation in the register address range from 10
Initialising Phase (see 11.3), using the Start Up Register Initialisation File.
Furthermore, the user may initialise the SL RC400 registers with values from the Register Initialisation File
executing the LoadConfig-Command (see 16.6.1).
Notes:
6.3.1
The content of the E²PROM memory block address 1 and 2 are used to initialise the SL RC400 registers
10
production are shown in chapter 6.3.2.
The assignment is the following:
hex
Make sure that all PreSet registers are not changed.
Make sure, that all register bits that are reserved for future use (RFU) are set to 0.
The Page-Register (addressed with 10
to 2F
Register Initialisation Files (Read/Write)
START UP REGISTER INITIALISATION FILE (READ/WRITE)
hex
during the Initialising Phase automatically. The default values written into the E²PROM during
hex
. It is in the range between about 80 to 120 Ω.
10
11
2F
Table 6-4: Byte Assignment for Register Initialisation at Start Up
hex
hex
hex
E²PROM Byte Address
(Block 1, Byte 0)
(Block 2, Byte 15)
hex
, 18
hex
, 20
64
hex
hex
, 28
Register Address
to 2F
hex
Product Specification Rev. 3.1 August 2004
) is skipped and not initialised.
10
11
2F
hex
ref,max,n
hex
hex
hex
is done automatically during the
and is measured with GsConfCW
Remark
Skipped
Copied
Copied
SL RC400