SLRC40001T/OFE,112 NXP Semiconductors, SLRC40001T/OFE,112 Datasheet - Page 95

IC I.CODE SLRC400 READER 32-SOIC

SLRC40001T/OFE,112

Manufacturer Part Number
SLRC40001T/OFE,112
Description
IC I.CODE SLRC400 READER 32-SOIC
Manufacturer
NXP Semiconductors
Series
I-Coder

Specifications of SLRC40001T/OFE,112

Rf Type
Read Only
Frequency
13.56MHz
Features
ISO15693, ISO18000-3
Package / Case
32-SOIC (0.300", 7.50mm Width)
Product
RFID Readers
Operating Temperature Range
- 25 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-1124-5
935269551112
SLRC400
SLRC41TOFED
Philips Semiconductors
I•CODE Reader IC
15.3 Registers Relevant for the Serial Signal Switch
The flags DecoderSource define the input signal for the internal Manchester decoder in the following way:
ModulatorSource defines the signal that modulates the transmitted 13.56 MHz carrier frequenzy. The
modulated signal drives the pins TX1 and TX2.
SIGOUTSelect defines the input signal for the internal Manchester decoder in the following way:
Note: To use SIGOUTSelect, the value of test signal control bit SignalToSIGOUT has to be 0.
ModulatorSource
DecoderSource
SIGOUTSelect
0
1
2
3
0
1
2
3
0
1
2
3
4
5
6
7
Table 15-2: Values for ModulatorSource
Constant 0
Output of the analog part. This is the default configuration.
RFU
RFU
Constant 0 (carrier frequency off at pin TX1 and TX2).
Constant 1 (continuous carrier frequency delivered at pin TX1 and TX2).
Modulation signal (envelope) from the internal coder. This is the default
configuration.
RFU
Constant 0
Constant 1
Modulation signal (envelope) from the internal coder.
Serial data stream that is to be transmitted
(same as for SIGOUTSelect = 2, but not coded by the “selected” pulse coder yet).
Output signal of the receiver circuit (label modulation signal regenerated
and delayed)
Output signal of the sub-carrier demodulator (Manchester-coded label signal)
RFU
RFU
Table 15-1: Values for DecoderSource
Table 15-3: Values for SIGOUTselect
95
Signal Routed to Pin SIGOUT
Input Signal for Modulator
Input Signal for Decoder
Product Specification Rev. 3.1 August 2004
SL RC400

Related parts for SLRC40001T/OFE,112