F39-JC3B Omron, F39-JC3B Datasheet - Page 15

Safety Light Curtain

F39-JC3B

Manufacturer Part Number
F39-JC3B
Description
Safety Light Curtain
Manufacturer
Omron
Datasheet

Specifications of F39-JC3B

Light Curtain Type
Safety
Accessory Type
Double-Ended Connector Cable
For Use With
F3SN Series Safety Light Curtain
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Section 1 Description
B-8
Item
Test functions
Safety-related functions
Connection method
Protection mode
Ambient temperature
Ambient humidity
Ambient light intensity
Insulation resistance
Dielectric strength
voltage
Degree of protection
Vibration resistance
Shock resistance
Cable *6
Materials
Weight
Accessories
Applicable standard
Type
*1.
*2.
*3. Flashing after a lapse of 30000 hours as an indicator of preventive maintenance.
*4.
*5.
*6.
*Packaged
Stand-alone
Series
connection
Please note that the operation may differ from conventional ON/OFF switching because of the safety circuit.
Available for the F3SN-A
For the factory setting, the manual reset mode is set to the start/restart interlock.
Using the F39-MC11 can select the start interlock or the restart interlock.
For the factory setting, the function is not set. It can be enabled with the F39-MC11.
When extending the cable, be sure to use a cable with at least same performance. Do not extend the cable
more than the length below. Be sure to route the F3SN-A cable separated from high-potential power lines or
through an exclusive conduit.
• In the case of no series connection: 100 m max.
• In the case of 2 sensors connected in series: 80 m max.
• In the case of 3 sensors connected in series: 30 m max.
F3SN-A
F3SN-A
F3SN-A
F3SN-A
F3SN-A
F3SN-A
• Self-test (After power ON, and during operation)
• External test (Light emission stop function by test input)
• Auto reset / manual reset (Interlock function) *4
• EDM (External device monitoring)
• Fixed blanking *5
• Floating blanking *5
M12 connector, 8 pins
Output short-circuit protection, Reverse polarity protection
During operation : -10 to 55°C (with no freezing)
During storage
During operation : 35 to 95% RH (with no condensation)
During storage
Incandescent lamp : 3,000 Ix max. (light intensity on the receiver surface)
Sunlight
20 MΩ min. (at 500 VDC)
1000 VAC 50/60 Hz 1 minute
IP65(IEC60529)
Normal operation : 10 to 55 Hz, double amplitude 0.7 mm, X, Y and Z directions 20 sweeps
Normal operation : 100 m/s2, X,Y and Z directions 1000 times
UL20276 (flame-resistant:), 8 cores (0.3 mm
allowable bending radius: R36 mm
Case
Cap
Optical cover
Cable
Calculate with the following equation:
Weight of light curtain with protective height of 180 mm to 738 mm (g)
Weight of light curtain with protective height of 747 mm to 1402 mm (g)
Weight of light curtain with protective height of 1417 mm to 1822 mm (g)
Test rod *7, Instruction manual, Mounting brackets (top and bottom),
Mounting brackets (intermediate)*8, Error mode label
Connector cap (Supplied with the –04, –05TS series)*9
IEC61496-1, EN61496-1 Type4 ESPE (Electro-Sensitive Protective Equipment)
IEC61496-2 Type4 AOPD (Active Opto-electronic Protective Devices)
P14
P14-02
P14-01
P14-03
P14-04
P14-05
: -30 to 70°C
: 35 to 95% RH
: 10,000 Ix max. (light intensity on the receiver surface)
: Aluminum
: Zinc die-cast
: PMMA (acrylic resin)
: Oil-proof PVC
P
F3SN-A
F3SN-A
F3SN-A
F3SN-A
F3SN-A
F3SN-A
-01, -03, -04, -05
P25
P25-02
P25-01
P25-03
P25-04
P25-05
= (Protective height + 100) x 2 + 1300)
= (Protective height + 100) x 2 + 1700)
= (Protective height + 100) x 2 + 2100)
2
x 4pairs), with braided wire shield,
F3SN-A
F3SN-A
F3SN-A
F3SN-A
F3SN-A
F3SN-A
P40
P40-02
P40-01
P40-03
P40-04
P40-05
F3SN-A
F3SN-A
F3SN-A
F3SN-A
F3SN-A
F3SN-A
P70
P70-02
P70-01
P70-03
P70-04
P70-05

Related parts for F39-JC3B