F39-JC3B Omron, F39-JC3B Datasheet - Page 5

Safety Light Curtain

F39-JC3B

Manufacturer Part Number
F39-JC3B
Description
Safety Light Curtain
Manufacturer
Omron
Datasheet

Specifications of F39-JC3B

Light Curtain Type
Safety
Accessory Type
Double-Ended Connector Cable
For Use With
F3SN Series Safety Light Curtain
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For your safety, always heed the followings:
For your safety, always heed the following:
B-iv
Installation Environment
Wiring and Mounting
Do not use any solvents such as paint thinners, benzine or acetone to clean the F3SN-A because it will
The F3SN-A cannot detect transparent or semi-transparent materials.
(1) The procedures of installation, inspection and maintenance in this manual should be read carefully.
(2) Loads must satisfy all the conditions below:
(3) All input lines and output lines of the F3SN-A should insulate against hazardous voltage levels (230 VAC,
(4) Be sure to dispose of the F3SN-A as industrial waste.
dissolve resin and paint.
etc.), not simply against 24 VDC, with double or reinforced insulation to protect against electrical shock.
In case of the combination with the F3SP-B1P, all relay output terminals (13-14, 23-24, 33-34, and
41-42) should insulate against hazardous voltage levels with basic insulation.
Is not short-circuited.
Is not used with current higher than the rating.
Do not install the F3SN-A in the following environments:
Do not use radio equipment, such as cellular phones, walkie-talkies, or transceivers with high
power, near the F3SN-A.
Be sure to turn OFF the power prior to wiring, otherwise the diagnostic function may prevent the
light curtain from operating.
Use shielded twisted pair cable (cross-sectional area: φ0.3mm
communication lines with a cable other than the dedicated cable (F39-JC ), and connect the shield
to the 0V line.
When replacing the cable connector with other connectors (e.g. resin connectors), make sure the
connector is rated IP54 or higher.
When the distance between the emitter and the receiver is less than 0.2m, there is a possibility of
the malfunction that the F3SN-A goes to the OFF-state momentary. Be sure to install the F3SN-A
within the rated operating range.
Check the signal name of all terminals for correct wiring.
Devise a measure to protect against mutual interference when using two or more sets of F3SN-A
beside one another.
Do not operate the control system until one second or more after turning ON the power of the
F3SN-A.
Be sure to route the F3SN-A cable separate from high-potential power lines or through an exclusive
conduit.
The emitter and receiver are to be mounted in parallel and facing one another.
Areas exposed to intense interference light, such as direct sunlight
Areas with high-humidity where condensation is likely to occur
Areas exposed to corrosive gases
Areas exposed to vibration or shock levels higher than specification provisions.
Areas where the light curtain may come in direct contact with water.
Correct Usage
Notice
2
or more) when extending the