LAN8187-JT SMSC, LAN8187-JT Datasheet - Page 69

Ethernet ICs HiPerfrm Ethrnt PHY

LAN8187-JT

Manufacturer Part Number
LAN8187-JT
Description
Ethernet ICs HiPerfrm Ethrnt PHY
Manufacturer
SMSC
Type
MII/RMII Ethernet Transceiverr
Datasheet

Specifications of LAN8187-JT

Ethernet Connection Type
10 Base-T, 100 Base-TX
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Product
Ethernet Transceivers
Number Of Transceivers
1
Standard Supported
802.3ab
Data Rate
10 MB, 100 MB
Supply Voltage (max)
3.3 V
Supply Voltage (min)
1.8 V
Supply Current (max)
39 mA, 81.6 mA
Maximum Operating Temperature
+ 70 C
Package / Case
TQFP-64
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN8187-JT
Manufacturer:
Standard
Quantity:
1 040
Part Number:
LAN8187-JT
Manufacturer:
STM
Quantity:
5 362
Part Number:
LAN8187-JT
Manufacturer:
SMSC
Quantity:
20 000
Company:
Part Number:
LAN8187-JT
Quantity:
114
±15kV ESD Protected MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX & flexPWR
Datasheet
SMSC LAN8187/LAN8187i
7.1.1.2
7.1.2
VDD33
INPUT VOLTAGE ON
DIGITAL PINS
VOLTAGE ON ANALOG
I/O PINS (RXP, RXN)
AMBIENT
TEMPERATURE
PARAMETER
EN61000-4-2 Performance
The EN61000-4-2 ESD specification is an international standard that addresses system-level immunity
to ESD strikes while the end equipment is operational. In contrast, the HBM ESD tests are performed
at the device level with the device powered down.
In addition to defining the ESD tests, EN61000-4-2 also categorizes the impact to equipment operation
when the strike occurs (ESD Result Classification). The LAN8187 maintains an ESD Result
Classification 1 or 2 when subjected to an EN61000-4-2 (level 4) ESD strike.
Both air discharge and contact discharge test techniques for applying stress conditions are defined by
the EN61000-4-2 ESD document.
AIR DISCHARGE
To perform this test, a charged electrode is moved close to the system being tested until a spark is
generated. All pins of the LAN8187 can safely dissipate +/- 15kV air discharges per the EN61000-4-2
specification without additional board level protection. This test is difficult to reproduce because the
discharge is influenced by such factors as humidity, the speed of approach of the electrode, and
construction of the test equipment.
CONTACT DISCHARGE
The uncharged electrode first contacts the pin to prepare this test, and then the probe tip is energized.
This yields more repeatable results, and is the preferred test method. All pins of the LAN8187 can
safely dissipate +/- 8kV contact discharges per the EN61000-4-2 specification without the need for
additional board level protection.
Operating Conditions
VDD33 to VSS
T
T
AEZG
Table 7.3 Recommended Operating Conditions
A
A
CONDITIONS
LAN8187-JT
LAN8187I-
DATASHEET
3.0
0.0
0.0
0
-40
MIN
69
®
3.3
TYP
Technology
3.6
VDDI
O
+3.6
V
70
+85
MAX
V
V
V
C
C
UNITS
For Commercial
Temperature
For Industrial Temperature
Revision 1.7 (03-04-11)
COMMENT

Related parts for LAN8187-JT