Specifications of EELXT360PE.A2-868068

Number Of Transceivers
1
Operating Supply Voltage (typ)
5V
Screening Level
Industrial
Mounting
Surface Mount
Operating Supply Voltage (min)
4.75V
Operating Supply Voltage (max)
5.25V
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Compliant
LXT360 Transceiver
Datasheet: Long Form
249231, Revision 2.1
24 January 2008
Figure 6
2.7.1.2
Cortina Systems
Local Loopback
Analog Loopback (ALOOP)
See
blocks. ALOOP operation disconnects the RTIP/RRING inputs from the line and routes the
transmit outputs back into the receive inputs. This tests the encoders/decoders, jitter
attenuator, transmitter, receiver and timing recovery sections.
In Hardware mode, ALOOP becomes active when the LLOOP pin is floating (i.e. Midrange).
In Host mode, setting bit CR2.EALOOP = 1 commands ALOOP . Note that ALOOP overrides
all other loopback modes.
®
LXT360 Integrated T1/E1 LH/SH Transceiver for DS1/DSX-1 or PRI Applications
Figure
7. Analog loopback (ALOOP) exercises the maximum number of functional
TM
TM
2.7 Diagnostic Mode Operation
Page 22