EP3C25F256C7N Altera, EP3C25F256C7N Datasheet - Page 91

IC CYCLONE III FPGA 256-FBGA

EP3C25F256C7N

Manufacturer Part Number
EP3C25F256C7N
Description
IC CYCLONE III FPGA 256-FBGA
Manufacturer
Altera
Series
Cyclone® IIIr

Specifications of EP3C25F256C7N

Number Of Logic Elements/cells
24624
Number Of Labs/clbs
1539
Total Ram Bits
608256
Number Of I /o
156
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
256-FBGA
Family Name
Cyclone III
Number Of Logic Blocks/elements
24624
# I/os (max)
156
Frequency (max)
437.5MHz
Process Technology
65nm
Operating Supply Voltage (typ)
1.2V
Logic Cells
24624
Ram Bits
608256
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
256
Package Type
FBGA
For Use With
544-2370 - KIT STARTER CYCLONE III EP3C25
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant
Other names
Q4433068

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C25F256C7N
Manufacturer:
ALTERA44
Quantity:
633
Part Number:
EP3C25F256C7N
Manufacturer:
ALTERA
Quantity:
3 513
Part Number:
EP3C25F256C7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C25F256C7N
Manufacturer:
ALTERA
0
Part Number:
EP3C25F256C7N
Manufacturer:
ALTERA
Quantity:
200
Part Number:
EP3C25F256C7N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP3C25F256C7NALTERA
Manufacturer:
ALTERA
0
Part Number:
EP3C25F256C7NG
Manufacturer:
ALTERA
0
Part Number:
EP3C25F256C7NG
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Chapter 5: Clock Networks and PLLs in the Cyclone III Device Family
PLL Reconfiguration
© December 2009
Altera Corporation
Post-Scale Counters (C0 to C4)
You can configure multiply or divide values and duty cycle of post-scale counters in
real time. Each counter has an 8-bit high time setting and an 8-bit low time setting.
The duty cycle is the ratio of output high or low time to the total cycle time, which is
the sum of the two. Additionally, these counters have two control bits, rbypass, for
bypassing the counter, and rselodd, to select the output clock duty cycle.
When the rbypass bit is set to 1, it bypasses the counter, resulting in a divide by one.
When this bit is set to 0, the PLL computes the effective division of the VCO output
frequency based on the high and low time counters. For example, if the post-scale
divide factor is 10, the high and low count values is set to 5 and 5 respectively, to
achieve a 50–50% duty cycle. The PLL implements this duty cycle by transitioning the
output clock from high-to-low on the rising edge of the VCO output clock. However,
a 4 and 6 setting for the high and low count values, respectively, would produce an
output clock with 40–60% duty cycle.
The rselodd bit indicates an odd divide factor for the VCO output frequency with a
50% duty cycle. For example, if the post-scale divide factor is three, the high and low
time count values are 2 and 1, respectively, to achieve this division. This implies a
67%–33% duty cycle. If you need a 50%–50% duty cycle, you must set the rselodd
control bit to 1 to achieve this duty cycle despite an odd division factor. The PLL
implements this duty cycle by transitioning the output clock from high-to-low on a
falling edge of the VCO output clock. When you set rselodd = 1, subtract 0.5 cycles
from the high time and add 0.5 cycles to the low time.
For example:
Scan Chain Description
Cyclone III device family PLLs have a 144-bit scan chain.
Table 5–4
Table 5–4. Cyclone III Device Family PLL Reprogramming Bits (Part 1 of 2)
C4
C3
C2
C1
C0
M
High time count = 2 cycles
Low time count = 1 cycle
rselodd = 1 effectively equals:
(1)
Block Name
High time count = 1.5 cycles
Low time count = 1.5 cycles
Duty cycle = (1.5/3)% high time count and (1.5/3)% low time count
lists the number of bits for each component of the PLL.
Counter
16
16
16
16
16
16
Number of Bits
Other
2
2
2
2
2
2
(2)
(2)
(2)
(2)
(2)
(2)
Cyclone III Device Handbook, Volume 1
Total
18
18
18
18
18
18
5–27

Related parts for EP3C25F256C7N