AT89LP828 Atmel Corporation, AT89LP828 Datasheet - Page 90

no-image

AT89LP828

Manufacturer Part Number
AT89LP828
Description
Manufacturer
Atmel Corporation
Datasheet

Specifications of AT89LP828

Flash (kbytes)
8 Kbytes
Max. Operating Frequency
25 MHz
Cpu
8051-1C
Max I/o Pins
30
Spi
1
Uart
1
Sram (kbytes)
0.75
Eeprom (bytes)
1024
Self Program Memory
IAP
Operating Voltage (vcc)
2.4 to 5.5
Timers
3
Isp
SPI/OCD
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89LP828-20AU
Manufacturer:
Atmel
Quantity:
360
Part Number:
AT89LP828-20AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89LP828-20JU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89LP828-20MH
Manufacturer:
Atmel
Quantity:
720
Part Number:
AT89LP828-20PU
Manufacturer:
NXP
Quantity:
3 942
Part Number:
AT89LP828-JU
Manufacturer:
Atmel
Quantity:
10 000
16.6
16.7
90
Framing Error Detection
Automatic Address Recognition
AT89LP428/828
In addition to all of its usual modes, the UART can perform framing error detection by looking for
missing stop bits, and automatic address recognition. When used for framing error detect, the
UART looks for missing stop bits in the communication. A missing bit will set the FE bit in the
SCON register. The FE bit shares the SCON.7 bit with SM0 and the function of SCON.7 is deter-
mined by PCON.6 (SMOD0). If SMOD0 is set then SCON.7 functions as FE. SCON.7 functions
as SM0 when SMOD0 is cleared. When used as FE, SCON.7 can only be cleared by software.
Automatic Address Recognition is a feature which allows the UART to recognize certain
addresses in the serial bit stream by using hardware to make the comparisons. This feature
saves a great deal of software overhead by eliminating the need for the software to examine
every serial address which passes by the serial port. This feature is enabled by setting the SM2
bit in SCON for Modes 1, 2 or 3. In the 9-bit UART modes, Mode 2 and Mode 3, the Receive
Interrupt flag (RI) will be automatically set when the received byte contains either the “Given”
address or the “Broadcast” address. The 9-bit mode requires that the 9th information bit be a “1”
to indicate that the received information is an address and not data.
In Mode 1 (8-bit) the RI flag will be set if SM2 is enabled and the information received has a valid
stop bit following the 8th address bits and the information is either a Given or Broadcast
address.
Automatic Address Recognition is not available during Mode 0.
Using the Automatic Address Recognition feature allows a master to selectively communicate
with one or more slaves by invoking the given slave address or addresses. All of the slaves may
be contacted by using the Broadcast address. Two special Function Registers are used to
define the slave’s address, SADDR, and the address mask, SADEN. SADEN is used to define
which bits in the SADDR are to be used and which bits are “don’t care”. The SADEN mask can
be logically ANDed with the SADDR to create the “Given” address which the master will use for
addressing each of the slaves. Use of the Given address allows multiple slaves to be recognized
while excluding others. The following examples show the versatility of this scheme:
Slave 0
Slave 1
In the previous example, SADDR is the same and the SADEN data is used to differentiate
between the two slaves. Slave 0 requires a “0” in bit 0 and it ignores bit 1. Slave 1 requires a “0”
in bit 1 and bit 0 is ignored. A unique address for slave 0 would be 1100 0010 since slave 1
requires a “0” in bit 1. A unique address for slave 1 would be 1100 0001 since a “1” in bit 0 will
exclude slave 0. Both slaves can be selected at the same time by an address which has bit 0 = 0
(for slave 0) and bit 1 = 0 (for slave 1). Thus, both could be addressed with 1100 0000.
SADDR = 1100 0000
SADEN = 1111 1101
Given = 1100 00X0
SADDR = 1100 0000
SADEN = 1111 1110
Given = 1100 000X
3654A–MICRO–8/09