mc68hc908gr16 Freescale Semiconductor, Inc, mc68hc908gr16 Datasheet - Page 39

no-image

mc68hc908gr16

Manufacturer Part Number
mc68hc908gr16
Description
M68hc08 Microcontrollers Microcontroller
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mc68hc908gr16CFA
Manufacturer:
FREESCALE
Quantity:
2 650
Part Number:
mc68hc908gr16CFA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc68hc908gr16CFA
Manufacturer:
FREESCALE
Quantity:
2 650
Part Number:
mc68hc908gr16CFA
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
mc68hc908gr16CFJ
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc68hc908gr16MFA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Programming tools are available from Freescale Semiconductor. Contact your local representative for
more information.
2.6.1.1 FLASH Control Register
The FLASH control register (FLCR) controls FLASH program and erase operations.
HVEN — High-Voltage Enable Bit
MASS — Mass Erase Control Bit
ERASE — Erase Control Bit
PGM — Program Control Bit
1. No security feature is absolutely secure. However, Freescale’s strategy is to make reading or copying the FLASH difficult for
Freescale Semiconductor
unauthorized users.
This read/write bit enables the charge pump to drive high voltages for program and erase operations
in the array. HVEN can only be set if either PGM = 1 or ERASE = 1 and the proper sequence for
program or erase is followed.
Setting this read/write bit configures the 16-Kbyte FLASH array for mass erase operation.
This read/write bit configures the memory for erase operation. ERASE is interlocked with the PGM bit
such that both bits cannot be equal to 1 or set to 1 at the same time.
This read/write bit configures the memory for program operation. PGM is interlocked with the ERASE
bit such that both bits cannot be equal to 1 or set to 1 at the same time.
1 = High voltage enabled to array and charge pump on
0 = High voltage disabled to array and charge pump off
1 = MASS erase operation selected
0 = PAGE erase operation selected
1 = Erase operation selected
0 = Erase operation unselected
1 = Program operation selected
0 = Program operation unselected
Address:
A security feature prevents viewing of the FLASH contents.
Reset:
Read:
Write:
$FE08
Bit 7
0
0
Figure 2-3. FLASH Control Register (FLCR)
= Unimplemented
6
0
0
MC68HC908GR16 Data Sheet, Rev. 5.0
5
0
0
NOTE
4
0
0
HVEN
3
0
MASS
2
0
(1)
ERASE
1
0
FLASH Memory (FLASH)
PGM
Bit 0
0
39