reduced the gain. The release threshold value can be used to set what is effectively a
minimum dynamic range, this is helpful as over limiting can reduce the dynamic range to
virtually zero and cause program material to sound “lifeless”.
In AC mode, the attack and release thresholds are set relative to full-scale. In DRC mode,
the attack threshold is set relative to the maximum volume setting of the channels mapped
to that limiter and the release threshold is set relative to the maximum volume setting plus
the attack threshold.
Table 65.
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
LxA[3:0]
Limiter attack rate vs LxA bits
3.1584
2.7072
2.2560
1.8048
1.3536
0.9024
0.4512
0.2256
0.1504
0.1123
0.0902
0.0752
0.0645
0.0564
0.0501
0.0451
Doc ID 13773 Rev 3
Attack Rate dB/ms
Register description
Fast
Slow
49/67