CDB5534U Cirrus Logic Inc, CDB5534U Datasheet - Page 10

EVAL BOARD FOR CS5534

CDB5534U

Manufacturer Part Number
CDB5534U
Description
EVAL BOARD FOR CS5534
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CDB5534U

Number Of Adc's
1
Number Of Bits
24
Sampling Rate (per Second)
3.84k
Data Interface
Serial
Inputs Per Adc
2 Single
Input Range
0 ~ 2.5 V
Power (typ) @ Conditions
35mW @ 5 V
Voltage Supply Source
Analog and Digital, Dual ±
Operating Temperature
-40°C ~ 85°C
Utilized Ic / Part
CS5534
Description/function
Audio DSPs
Operating Supply Voltage
5 V
Product
Audio Modules
For Use With/related Products
C8051F320
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1016
CDB5534U
2.2.1
Start-Up Window
When the evaluation program is launched, the Start-Up window will appear. This window contains infor-
mation concerning the software’s title, revision number, copyright date, etc.
Figure 4. CDB5534U Start-Up Screen
At the top of the screen is a menu bar which displays user options. The menu bar item Window is initially
disabled to prevent conflicts with other serial communications devices. After selecting the data source in
the Options menu, the Window menu item will become available.
2.2.1.1
Options
The Options menu item allows the user to select the source of the data and to configure the appearance
of the graphs. The user has two options for the data source: USB and File. If the USB setup is selected,
the evaluation software will be ready to communicate with the CDB5534U via the USB connection. At this
point, the Part menu item is active and the appropriate CS553x device can be selected. If the File source
is selected, the evaluation software will prompt the user to select the appropriate data file. This option al-
lows the user to view previously captured data without having a CDB5534U connected to the PC. See
Section 2.5 for more details.
The plot options window can be accessed by pulling down the Options menu and clicking on Plot Options.
In this window, the user can change the background color, the plot line color, and the peak indicator color.
The harmonic and peak indicators can also be turned on or off in this window.
10
DS289DB6

Related parts for CDB5534U