CDB5534U Cirrus Logic Inc, CDB5534U Datasheet - Page 14

EVAL BOARD FOR CS5534

CDB5534U

Manufacturer Part Number
CDB5534U
Description
EVAL BOARD FOR CS5534
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CDB5534U

Number Of Adc's
1
Number Of Bits
24
Sampling Rate (per Second)
3.84k
Data Interface
Serial
Inputs Per Adc
2 Single
Input Range
0 ~ 2.5 V
Power (typ) @ Conditions
35mW @ 5 V
Voltage Supply Source
Analog and Digital, Dual ±
Operating Temperature
-40°C ~ 85°C
Utilized Ic / Part
CS5534
Description/function
Audio DSPs
Operating Supply Voltage
5 V
Product
Audio Modules
For Use With/related Products
C8051F320
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1016
CDB5534U
2.2.3
Data Collection Window
The Data Collection Window (Figure 8) allows the user to collect sample sets of data from the CS5534
and analyze them using time domain, FFT, and histogram plots. The Data Collection Window is accessi-
ble through the Window option, or by pressing F3.
Figure 8. CDB5534U Data Collection Window
Time Domain / FFT / Histogram Selector: This menu selects the type of data processing to perform on
the collected data and display in the plot area. Refer to the section on Analyzing Data for more information.
Collect Button: This button will collect data from the part, to be analyzed in the plot area. See the section
on Collecting Data Sets for more information.
Config Button: This button will bring up the configuration window, in which the user can modify the data
collection specifications. See the discussion of the Config Window in this document.
Output Button: This button will bring up a window in which the user can output the data to a data file for
later use, print out a plot, or print out the entire screen.
Zoom Button: This button allows the user to zoom in on the plot by selecting two points in the plot area.
Press the Restore button to return to the normal data plot, or press the Zoom button again to zoom in even
further.
Setup Select Box: This box determines the setup number to use when performing conversions. See the
CS5534 datasheet for more details on the functionality of the Channel Setup Registers.
14
DS289DB6

Related parts for CDB5534U