EP9312-IB Cirrus Logic Inc, EP9312-IB Datasheet - Page 262

IC ARM920T MCU 200MHZ 352-PBGA

EP9312-IB

Manufacturer Part Number
EP9312-IB
Description
IC ARM920T MCU 200MHZ 352-PBGA
Manufacturer
Cirrus Logic Inc
Series
EP9r
Datasheets

Specifications of EP9312-IB

Core Processor
ARM9
Core Size
16/32-Bit
Speed
200MHz
Connectivity
EBI/EMI, EIDE, Ethernet, I²C, IrDA, Keypad/Touchscreen, SPI, UART/USART, USB
Peripherals
AC'97, DMA, I&sup2:S, LCD, LED, MaverickKey, POR, PWM, WDT
Number Of I /o
16
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 3.6 V
Data Converters
A/D 8x12b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
352-BGA
Processor Series
EP93xx
Core
ARM920T
Data Bus Width
32 bit
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
No
Other names
598-1259

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP9312-IB
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
EP9312-IBZ
Manufacturer:
CIRRUS
Quantity:
30
Part Number:
EP9312-IBZ
Manufacturer:
HITTITE
Quantity:
1 200
Part Number:
EP9312-IBZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
7
HSigStrtStop
7-80
Raster Engine With Analog/LCD Integrated Timing and Interface
EP93xx User’s Guide
31
15
Bit Descriptions:
Address: 0x8003_020C
Default: 0x0000_0000
Definition: Horizontal Signature Bounds Start/Stop register
Bit Descriptions:
30
14
RSVD
RSVD
29
13
28
12
RSVD:
STOP:
STRT:
RSVD:
STOP:
STRT:
27
11
26
10
Copyright 2007 Cirrus Logic
25
9
Reserved - Unknown during read
Stop - Read/Write
The STOP value is the value of the Vertical down counter
at which the VSIGEN signal becomes inactive (stops).This
indicates the end of the signature calculation for the
Vertical frame. VSIGEN is an internal block signal. The
SIG_ENABLE control to the video signature analyzer is
enabled by the logical AND of VSIGEN and HSIGEN.
Start - Read/Write
The STRT value is the value of the Vertical down counter
at which the VSIGEN signal becomes active (starts).This
indicates the start of the signature calculation for the
Vertical frame. VSIGEN is an internal block signal. The
SIG_ENABLE control to the video signature analyzer is
enabled by the logical AND of VSIGEN and HSIGEN.
Reserved - Unknown during read
Stop - Read/Write
The STOP value is the value of the horizontal down
counter at which the HSIGEN signal becomes inactive
(stops). This indicates the end of the signature calculation
for a horizontal line. HSIGEN is an internal block signal.
The SIG_ENABLE control to the video signature analyzer
is enabled by the logical AND of VSIGEN and HSIGEN.
Start - Read/Write
24
8
23
7
22
6
STOP
STRT
21
5
20
4
19
3
18
2
17
1
DS785UM1
16
0