STEVAL-IHP001V3 STMicroelectronics, STEVAL-IHP001V3 Datasheet - Page 38

BOARD SMART PLUG STM32 SPZB260PR

STEVAL-IHP001V3

Manufacturer Part Number
STEVAL-IHP001V3
Description
BOARD SMART PLUG STM32 SPZB260PR
Manufacturer
STMicroelectronics
Series
Zigbee™ SmartPlugr
Type
Microcontroller, Energy Meteringr
Datasheets

Specifications of STEVAL-IHP001V3

Frequency
2.4GHz
For Use With/related Products
STM32F10x, SPZB260-PRO, STPM01
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-10677
Theory of operation
Table 17.
38/60
Bit #
0
1
2
3
4
5
6
7
Precharge
Reserved
Reserved
Signal
PUMP
BANK
name
CSEL
WE
RD
Mode signals description
– RD mode signal has been already described in the SPI section but there is another
– PUMP: when set, the PUMP mode signal transform the MOP and MON pins to act as
– CSEL In normal operation, if the anti-tamper module is not activated (see PST
– WE (write enable): This mode signal is used to permanently write to the OTP antifuse
– Precharge: this command swaps the sequence of data record read, allowing the
value
Bit
implied function of the signal RD. When it is set, each sense amplifier is disconnected
from corresponding antifuse element and this way, its 3 V NMOS gate is protected
from the high voltage of VOTP during permanent write operation. This means that as
long as the VOTP voltage reads more than 3 V, the signal RD should be set.
driving signals to implement a charge-pump DC-DC converter (see schematic page
36). This feature is useful in order to boost the V
generate the VOTP voltage (14 V to 20 V) needed to program the OTP antifuse
elements.
configuration bits) the STPM01 will select the channel 1 as source of current
information. For debug or calibration purposes it is possible to select channel 2 as
source of current channel signal when the tamper module is disabled. This is done
setting CSEL mode bit.
element. When this bit is not set, any write to the configuration bit is recorded in the
shadow latches. When this bit is set the writing is recorded both in the shadow latch
and in the OTP antifuse element.
reading of the last four data records as first and the first four as second. The reading
sequence will be 5, 6, 7, 8, 1, 2, 3, 4. Differently from the other mode signals, the
precharge command is not retained inside the STPM01, in fact it should be sent each
time before the reading of the data records. This is the only command that can be
sent to STPM01 when the TSTD bit has been set.
0
1
0
1
0
1
0
1
0
1
1
Used for RC startup procedure
MOP and MON operates normally
MOP and MON provides the driving signals to implement a
charge-pump DC-DC converter
Current Channel 1 selected when tamper is disabled
Channel 2 selected when tamper is disabled
The 56 Configuration bits originated by OTP antifuses
The 56 Configuration bits originated by shadow latches
Any writing in the configuration bits is recorded in the
shadow latches
Any writing in the configuration bits is recorded both in the
shadow latches and in the OTP antifuse elements
Swap the 32 bits data records reading. From
1,2,3,4,5,6,7,8, to 5,6,7,8,1,2,3,4 and viceversa
Doc ID 10853 Rev 7
Status
CC
supply voltage of the STPM01 to
command
0111100x
0111000x
1111000x
0111001x
1111001x
1111100x
0111101x
1111101x
0111110x
1111110x
1111111x
Binary
command
FC or FD
7C or 7D
7A or 7B
FA or FB
F0 or F1
F2 or F3
F8 or F9
70 or 71
72 or 73
78 or 79
Hex
STPM01
FF