AT86RF231-ZUR Atmel, AT86RF231-ZUR Datasheet - Page 40

no-image

AT86RF231-ZUR

Manufacturer Part Number
AT86RF231-ZUR
Description
IC RADIO TXRX 2.4GHZ 32-VQFN
Manufacturer
Atmel
Datasheet

Specifications of AT86RF231-ZUR

Frequency
2.4GHz
Data Rate - Maximum
2Mbps
Modulation Or Protocol
802.15.4 Zigbee, 6LoWPAN, RF4CE, SP100, WirelessHART™, ISM
Applications
Industrial Monitoring and Control, Wireless Alarm and Security Systems
Power - Output
-17dBm ~ 3dBm
Sensitivity
-101dBm
Voltage - Supply
1.8 V ~ 3.6 V
Current - Receiving
12.3mA
Current - Transmitting
14mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
32-VQFN Exposed Pad, 32-HVQFN, 32-SQFN, 32-DHVQFN
Number Of Receivers
1
Number Of Transmitters
1
Wireless Frequency
2405 MHz to 2480 MHz
Interface Type
SPI
Noise Figure
6 dB
Output Power
20 dB
Operating Supply Voltage
2.5 V, 3.3 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Maximum Supply Current
12.3 mA
Minimum Operating Temperature
- 40 C
Modulation
OQPSK
Protocol Supported
802.15.4
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
7.1.4.2
7.1.4.3
8111C–MCU Wireless–09/09
Wake-up Procedure
PLL_ON and RX_ON States
The wake-up procedure from SLEEP state is shown in
Figure 7-4.
The radio transceivers SLEEP state is left by releasing pin SLP_TR to logic low. This restarts the
XOSC and DVREG. After t
internal clock signal is available and provided to pin 17 (CLKM), if CLKM was enabled.
This procedure is similar to the Power-On Procedure. However the radio transceiver continues
the state change automatically to the TRX_OFF state. During this the filter-tuning network (FTN)
calibration is performed. Entering TRX_OFF state is signaled by IRQ_4 (AWAKE_END), if this
interrupt was enabled by the appropriate mask register bit.
The transition from TRX_OFF to PLL_ON and RX_ON mode is shown in
Figure 7-5.
Note:
In TRX_OFF state, entering the commands PLL_ON or RX_ON initiates a ramp-up sequence of
the internal 1.8V voltage regulator for the analog domain (AVREG). RX_ON state can be
entered any time from PLL_ON state regardless whether the PLL has already locked, which is
indicated by IRQ_0 (PLL_LOCK).
Event
State
Block
Time
Event
State
Block
Command
Time
If TRX_CMD = RX_ON in TRX_OFF state RX_ON state is entered immediately, even if the PLL
has not settled.
SLEEP
TRX_OFF
Wake-up Procedure from SLEEP State
Transmission from TRX_OFF to PLL_ON and RX_ON State
0
SLP_TR = L
XOSC, DVREG
0
AVREG
PLL_ON
TR2
= 380 µs (typ.) the radio transceiver enters TRX_OFF state. The
100
t
TR4
t
TR2
CLKM on
PLL
200
FTN
100
IRQ_4 (AWAKE_END)
TRX_OFF
XOSC, DVREG
IRQ_0 (PLL_LOCK)
PLL_ON
Figure 7-4 on page
R_ON
RX_ON
RX
t
TR8
400
Figure 7-5 on page
AT86RF231
40.
Time [µs]
Time [µs]
40.
40