XTH9-MI-128 Digi International/Maxstream, XTH9-MI-128 Datasheet - Page 24

no-image

XTH9-MI-128

Manufacturer Part Number
XTH9-MI-128
Description
MODULE RF 900MHZ 1W 115K W/MMCX
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XTH9-MI-128

Frequency
900MHz
Data Rate - Maximum
230kbps
Modulation Or Protocol
FHSS, FSK
Power - Output
30dBm
Sensitivity
-110dBm
Voltage - Supply
3.3V, 5V
Current - Receiving
80mA
Current - Transmitting
260mA
Data Interface
Connector, 2 x 10 Header
Antenna Connector
MMCX
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
XTend™ RF Module ‐ Product Manual v2.x6x
BT (Guard Time Before) Command
CC (Command Sequence Character) Command
CD (GPO2 Configuration) Command
CF (Number Base) Command
<AT Command Mode Options> BT Command is
used to set the DI pin silence time that must pre-
cede the command sequence character (CC com-
mand) of the AT Command Mode sequence.
Refer to the ‘AT Command Mode’ section [p17] for
more information regarding the AT Command
Mode Sequence.
<AT Command Mode Options> The CC command
is used to set/read the ASCII character used
between guard times of the AT Command Mode
Sequence (BT + CC + AT). This sequence enters
the module into AT Command Mode so that data
entering the module (from the host) is recognized
as commands instead of payload.
Refer to the ‘AT Command Mode’ section [p17] for
more information regarding the AT Command
Mode Sequence.
<Serial Interfacing> CD Command is used to
select/read the behavior of the GPO2 line (pin 3).
<Command Mode Options> CF command is used
to set/read the command formatting setting.
The following commands are always entered and
read in hex, no matter the CF setting:
© 2010 Digi Internatonal, Inc.
VR (Firmware Version)
HV (Hardware Version)
KY (AES Encryption Key)
AT Command: ATCF
Parameter Range: 0 – 2
Default Parameter Value: 1
Number of bytes returned: 1
AT Command: ATBT
Binary Command: 0x04
Parameter Range: 0 - 0xFFFF
Default Parameter Value: 0x0A
Number of bytes returned: 2
AT Command: ATCC
Binary Command: 0x13 (19 decimal)
Parameter Range: 0x20 - 0x7F
Default Parameter Value: 0x2B (ASCII “+”)
Number of bytes returned: 1
Related Commands: AT (Guard Time After), BT
(Guard Time Before)
AT Command: ATCD
Binary Command: 0x28 (40 decimal)
Parameter Range: 0 - 8 (standard rates)
Default Parameter Value: 2
Number of bytes returned: 1
Parameter
Parameter
0
1
2
0
1
2
3
4
commands may output units
Commands utilize default
default number base; no
All commands forced to
unsigned, unit-less hex
Commands utilize their
number base; decimal
units are output
Configuration
(valid address only)
Configuration
Default High
Default Low
(reserved)
RX LED
RX LED
     24

Related parts for XTH9-MI-128