XTH9-MI-128 Digi International/Maxstream, XTH9-MI-128 Datasheet - Page 77

no-image

XTH9-MI-128

Manufacturer Part Number
XTH9-MI-128
Description
MODULE RF 900MHZ 1W 115K W/MMCX
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XTH9-MI-128

Frequency
900MHz
Data Rate - Maximum
230kbps
Modulation Or Protocol
FHSS, FSK
Power - Output
30dBm
Sensitivity
-110dBm
Voltage - Supply
3.3V, 5V
Current - Receiving
80mA
Current - Transmitting
260mA
Data Interface
Connector, 2 x 10 Header
Antenna Connector
MMCX
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
XTend™ RF Module ‐ Product Manual v2.x6x
RS-485 (4-wire) & RS-422 Operation
DIP Switch Settings and Serial Port Connections
Figure B‐22.
RS‐485 (4‐wire)& RS‐422 w/ Termination (optional)
Termination is the 120  resistor between T+ and T‐.
DIP Switch settings are read and applied only while powering‐on.
Figure B‐20.
RS‐485 (4‐wire) & RS‐422 
DIP Switch Settings
Note: Refer to Figures B-09 and B-10 for RJ-45 connector pin designations used in 
RS-485/422 environments.
Table B‐06. RS‐485/422 (4‐wire) Signals and their implementations on the XTend Module Assembly
© 2010 Digi Internatonal, Inc.
DB-9 Pin
1, 4, 6
2
3
5
7
8
9
RS-485/422
R+ (RB)
R- (RA)
T+ (TB)
Name
T- (TA)
PWR
GND
Transmit Negative
Receive Negative
Transmit Positive
Receive Positive
Description
Signal Ground
Data Line
Data Line
Data Line
Data Line
Power
Figure B‐21.
Pins used on the female RS‐232 (DB‐9) 
Serial Connector 
not used
Serial data received by the XTend Module Assembly
Serial data received by the XTend Module Assembly
Serial data sent from the XTend Module Assembly
Serial data sent from the XTend Module Assembly
Optional power input that is connected internally
to the front power connector
Implementation
Ground
     77