XTH9-MI-128 Digi International/Maxstream, XTH9-MI-128 Datasheet - Page 35

no-image

XTH9-MI-128

Manufacturer Part Number
XTH9-MI-128
Description
MODULE RF 900MHZ 1W 115K W/MMCX
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XTH9-MI-128

Frequency
900MHz
Data Rate - Maximum
230kbps
Modulation Or Protocol
FHSS, FSK
Power - Output
30dBm
Sensitivity
-110dBm
Voltage - Supply
3.3V, 5V
Current - Receiving
80mA
Current - Transmitting
260mA
Data Interface
Connector, 2 x 10 Header
Antenna Connector
MMCX
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
XTend™ RF Module ‐ Product Manual v2.x6x
RR (Retries) Command
RT (GPI1 Configuration) Command
SB (Stop Bits) Command
SH (Serial Number High) Command
SL (Serial Number Low) Command
<Networking & Security> The RR command is
used to set/read the maximum number of retries
sent for a given RF packet. When RR Command is
enabled (RR>0), RF packet retries and ACKs
(acknowledgements) are enabled.
Exceptions: If the MT command in enabled
(MT>0) or if a broadcast Destination Address is
used (DT = 0xFFFF); RF packet retries and ACKs are disabled.
After transmitting a packet, the transmitting RF module waits to receive an acknowledgement
from a receiving module. If the acknowledgement is not received in the period of time specified by
RN (Delay Slots) Command, the original packet is transmitted again. The RF packet is transmitted
repeatedly until an acknowledgement is received or until the packet is sent RR times.
<Serial Interfacing> The RT command is used to
set/read the behavior of the GPI1 ping (pin 10) of
the RF Module. The pin can be configured to
enable binary programming or RTS flow control.
<Serial Interfacing> The SB Command is used to
set/read the number of stop bits in the data
packet.
<Diagnostics> SH Command is used to set/read
the serial number high word of the RF module.
<Diagnostics> SL Command is used to set/read
the serial number low word of the RF module.
© 2010 Digi Internatonal, Inc.
AT Command: ATRT
Binary Command: 0x16 (22 decimal)
Parameter Range:0 - 2
Default Parameter Value: 0
Number of bytes returned: 1
AT Command: ATRR
Binary Command: 0x18 (24 decimal)
Parameter Range:0 - 0xFF
Default Parameter Value: 0x0A (10 decimal)
Number of bytes returned: 1
AT Command: ATSB
Binary Command: 0x37 (55 decimal)
Parameter Range: 0 - 1
Default Parameter Value: 0
Number of bytes returned: 1
AT Command: ATSH
Binary Command: 0x25 (37 decimal)
Parameter Range (read-only): 0 - 0xFFFF
Default Parameter Value: varies
Number of bytes returned: 2
Related Commands: SL (Serial Number Low)
AT Command: ATSL
Binary Command: 0x26 (38 decimal)
Parameter Range (read-only): 0 - 0xFFFF
Default Parameter Value: varies
Number of bytes returned: 2
Related Commands: SH (Serial Number High)
Parameter
0
1
Configuration
2 stop bits
1 stop bit
     35

Related parts for XTH9-MI-128