XTH9-MI-128 Digi International/Maxstream, XTH9-MI-128 Datasheet - Page 40

no-image

XTH9-MI-128

Manufacturer Part Number
XTH9-MI-128
Description
MODULE RF 900MHZ 1W 115K W/MMCX
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XTH9-MI-128

Frequency
900MHz
Data Rate - Maximum
230kbps
Modulation Or Protocol
FHSS, FSK
Power - Output
30dBm
Sensitivity
-110dBm
Voltage - Supply
3.3V, 5V
Current - Receiving
80mA
Current - Transmitting
260mA
Data Interface
Connector, 2 x 10 Header
Antenna Connector
MMCX
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
XTend™ RF Module ‐ Product Manual v2.x6x
API Types
Checksum
RF Module Status
Data bytes that need to be escaped:
Note: In the above example, the length of the raw data (excluding the checksum) is 0x0002 and
the checksum of the non-escaped data (excluding frame delimiter and length) is calculated as:
0xFF - (0x23 + 0x11) = (0xFF - 0x34) = 0xCB.
To test data integrity, a checksum is calculated and verified on non-escaped data.
To calculate: Not including frame delimiters and length, add all bytes keeping only the lowest 8
bits of the result and subtract from 0xFF.
To verify: Add all bytes (include checksum, but not the delimiter and length). If the checksum is
correct, the sum will equal 0xFF.
Frame data of the UART data frame forms an API-specific structure as follows:
Figure 3‐03. UART Data Frame & API‐specific Structure:
The cmdID frame (API-identifier) indicates which API messages will be contained in the cmdData
frame (Identifier-specific data). Refer to the sections that follow for more information regarding
the supported API types. Note that multi-byte values are sent big endian.
API Identifier: 0x8A
RF module status messages are sent from the module in response to specific conditions.
Figure 3‐04.  RF Module Status Frames
Example - Raw UART Data Frame (before escaping interfering bytes): 
0x7E 0x00 0x02 0x23 0x11 0xCB
0x11 needs to be escaped which results in the following frame: 
0x7E 0x00 0x02 0x23 0x7D 0x31 0xCB
© 2010 Digi Internatonal, Inc.
• 0x7E – Frame Delimiter
• 0x7D – Escape
• 0x11 – XON
• 0x13 – XOFF
Start Delimiter
Start Delimiter
(Byte 1)
0x7E
0x7E
MSB
MSB
Length
(Bytes 2-3)
Length
LSB
API Identifier
LSB
API Identifier
0x8A
cmdID
API-specific Structure
0 = Hardware reset
1 = Watchdog timer reset
API-specific Structure
Frame Data
Frame Data
(Bytes 4- n)
Identifier-specific Data
Status (Byte 5)
Identifier-specific Data
cmdData
cmdData
Checksum
1 Byte
(Byte n + 1)