XTH9-MI-128 Digi International/Maxstream, XTH9-MI-128 Datasheet - Page 72

no-image

XTH9-MI-128

Manufacturer Part Number
XTH9-MI-128
Description
MODULE RF 900MHZ 1W 115K W/MMCX
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XTH9-MI-128

Frequency
900MHz
Data Rate - Maximum
230kbps
Modulation Or Protocol
FHSS, FSK
Power - Output
30dBm
Sensitivity
-110dBm
Voltage - Supply
3.3V, 5V
Current - Receiving
80mA
Current - Transmitting
260mA
Data Interface
Connector, 2 x 10 Header
Antenna Connector
MMCX
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
XTend™ RF Module ‐ Product Manual v2.x6x
Adapters
NULL Modem Adapter (male-to-male)
NULL Modem Adapter (female-to-female)
Serial Loopback Adapter
The development kit includes several adapters that facilitate the following functions:
Part Number: JD2D2-CDN-A (Black, DB-9 M-M) The male-to-male NULL modem adapter is
used to connect two DCE devices. A DCE device connects with a straight-through cable to the male
serial port of a computer (DTE).
Figure B‐05. Male NULL modem adapter and pinouts
Figure B‐06. Example of a Digi Radio Modem (DCE Device) connecting to another DCE device)
Part Number: JD3D3-CDN-A (Gray, DB-9 F-F) The female-to-female NULL modem adapter is
used to verify serial cabling is functioning properly. To test cables, insert the female-to-female
NULL modem adapter in place of a pair of module assemblies (RS-232 interface board + XTend RF
Module) and test the connection without modules in the connection.
Figure B‐07. Female NULL modem adapter and pinouts
Part Number: JD2D3-CDL-A (Red, DB-9 M-F) The serial loopback adapter is used for range
testing. During a range test, the serial loopback adapter configures the module to function as a
repeater by looping serial data back into the radio for retransmission.
Figure B‐08. Serial loopback adapter and pinouts
© 2010 Digi Internatonal, Inc.
• Performing Range Tests
• Testing Cables
• Connecting to other RS-232 DCE and DTE devices
• Connecting to terminal blocks or RJ-45 (for RS-485/422 devices)