MMA7455LT Freescale Semiconductor, MMA7455LT Datasheet - Page 12

Board Mount Accelerometers 3-AXIS DIGITAL 2 4 8G

MMA7455LT

Manufacturer Part Number
MMA7455LT
Description
Board Mount Accelerometers 3-AXIS DIGITAL 2 4 8G
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MMA7455LT

Sensing Axis
X, Y, Z
Acceleration
2 g, 4 g, 8 g
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.4 V
Supply Current
400 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Sensitivity
64 LSB/g
Package / Case
LGA-14
Output Type
Digital
Acceleration Range
± 2g, ± 4g, ± 8g
No. Of Axes
3
Sensor Case Style
LGA
No. Of Pins
14
Supply Voltage Range
2.4V To 3.6V
Operating Temperature Range
-40°C To +85°C
Filter Terminals
SMD
Rohs Compliant
Yes
Ic Interface Type
I2C, SPI
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MMA7455LT
Manufacturer:
FREESCALE
Quantity:
18 300
Part Number:
MMA7455LT
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MMA7455LT
Quantity:
10
$1B: Pulse Detection Threshold Limit Value (Read/Write)
PULSE DETECTION
In Pulse Mode, all functions can be active including measurements, level detections and pulse detection. There are two interrupt
pins available for detection of level and pulse conditions. The pulse detection has several timing windows associated with it. A
single pulse and a double pulse can be detected. Also freefall can be detected. The interrupt pins can be assigned to detect the
first pulse on one interrupt and the second pulse on the other interrupt. This is explained on
ing & Detecting Interrupts
By default all three axes are enabled and the detection range is 8g only. X and/or Y and/or Z can be disabled. There is a choice
between doing a detection for Motion detection vs. doing a detection for Freefall.
$18: Control 1 (Read/Write): Disable X, Y or Z for Pulse Detection
This allows the user to define how many axes to use for detection. All axes are enabled by default. To disable write 1
XDA: Disable X
YDA: Disable Y
ZDA: Disable Z.
$19: Control 2 (Read/Write): Motion Detection (OR condition) or Freefall Detection (AND condition)
PDPL
0: Pulse detection polarity is positive and detecting condition is OR 3 axes.
1: Pulse detection polarity is negative and detecting condition is AND 3 axes.
CASE 1: Single Pulse Motion Detection: X or Y or Z > Pulse Threshold for Time < Pulse Duration
For motion detection with single pulse the device must be in pulse mode. PDPL in Register $19 =0 for “OR” motion condition.
The Pulse threshold must be set in Register $1B and the pulse duration time window must also be set using Register $1C. The
pulse must be detected before the time window closes for the interrupt to trigger.
$1C: Pulse Duration Value (Read/Write)
12
MMA7455L
PDTH[7]
DFBW
PD[7]
D7
D7
D7
D7
0
0
--
0
0
PDTH[6]
THOPT
PD[6]
D6
D6
D6
D6
0
--
0
0
0
section.
PDTH[5]
PD[5]
ZDA
D5
D5
D5
D5
0
--
0
0
0
PDTH[4]
PD[4]
YDA
D4
D4
D4
D4
--
0
0
0
0
PDTH[3]
PD[3]
XDA
D3
D3
D3
D3
0
--
0
0
0
INTREG[1]
PDTH[2]
DRVO
PD[2]
D2
D2
D2
D2
0
0
0
0
INTREG[0]
PDTH[1]
PDPL
PD[1]
D1
D1
Page
D1
D1
0
0
0
0
15, under the
Freescale Semiconductor
PDTH[0]
INTPIN
LDPL
PD[0]
D0
D0
D0
D0
1
0
0
0
Assigning, Clear-
Reg $1C
Function
Function
Reg $19
Reg $1B
Reg $18
Function
Function
Default
Default
Default
Default
Sensors

Related parts for MMA7455LT