ISL5416KIZ Intersil, ISL5416KIZ Datasheet - Page 38

no-image

ISL5416KIZ

Manufacturer Part Number
ISL5416KIZ
Description
IC,Downconverter,BGA,256PIN,PLASTIC
Manufacturer
Intersil
Datasheet

Specifications of ISL5416KIZ

Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISL5416KIZ
Manufacturer:
INTERSIL
Quantity:
2
Part Number:
ISL5416KIZ
Manufacturer:
INTERSIL
Quantity:
20 000
The ISL5416 can be programmed to respond to the
synchronization inputs, SYNCIn1 and SYNCIn2, in a number
of ways. This register controls the range control response to
P(31:0)
P(31:0)
31:27
26:16
15:11
30:20
10:0
14:4
31
19
18
17
16
15
3
2
1
0
TABLE 27. XOUT DATA VERSUS TIME SLOT ROUTING, TIME SLOTS 6, 7 (IWA = 0*04h) RESET STATE = 0x00000000h
RESERVED.
SLOT 7 CONTROL (see Table 24)
RESERVED.
SLOT 6 CONTROL (see Table 24)
ENABLE SYNCIn2 TO RANGE CONTROL.
1 = range control block responds to SYNCIn2 according to bits 19:16 settings.
0 = range control block does not respond to SYNCIn2.
RESERVED. Set to 0.
READ UPDATE ON SYNCIn2.
1 = attenuator control accumulator contents are transferred to the read holding register on SYNCIn2.
LOAD ACCUMULATOR ON SYNCIn2.
1 = attenuator control accumulator is loaded from the uP load register (0*19) on a SYNCIn2.
RANGE CONTROL STARTUP ON SYNCIn2.
1 = enable range control on SYNCIn2 if 0*10, bit 1 is set. Range control is disabled on reset or by writing a zero to IWA = 0*10h, bit
0. If this bit is set, bit 0 of 0*10 is set on a SYNCIn2.
TIMING RESET ON SYNCIn2.
1 = reset range control timing on SYNCIn2 if 0*10, bit 1 is set. Once started, the timers will run until disabled (bit 1 of 0*10h or HW
reset).
ENABLE SYNCIn1 TO RANGE CONTROL.
1 = range control block responds to SYNCIn1 according to bits 3:0 settings.
0 = range control block does not respond to SYNCIn1.
RESERVED. Set to 0.
READ UPDATE ON SYNCIn1.
1 = attenuator control accumulator contents are transferred to the read holding register on SYNCIn1.
LOAD ACCUMULATOR ON SYNCIn1.
1 = attenuator control accumulator is loaded from the uP load register (0*19) on a SYNCIn1.
RANGE CONTROL STARTUP ON SYNCIn1.
1 = enable VGA startup control on SYNCIn2 if 0*10, bit 1 is set. Range control is disabled on reset or by writing a zero to 0*10, bit 0.
If this bit is set, bit 0 of 0*10 is set on a SYNCIn1. Disable on reset.
TIMING RESET ON SYNCIn1.
1 = reset range control timing on SYNCIn1 if 0*10, bit 1 is set. Once started, the timers will run until disabled (bit 1 of 0*10h or HW
reset).
TABLE 28. INPUT SYNCIn1/SYNCIn2 FUNCTION SELECT (IWA = 0*05h) RESET STATE = 0x00000000h
38
ISL5416
FUNCTION
FUNCTION
the SYNC inputs. The response of the channels to the SYNC
inputs is controlled by IWA = *000h. CLKO start up from
SYNCIn1 or SYNCIn2 is controlled in IWA = 0000h.