LM93CIMT National Semiconductor, LM93CIMT Datasheet - Page 31

no-image

LM93CIMT

Manufacturer Part Number
LM93CIMT
Description
Microprocessor Support IC
Manufacturer
National Semiconductor
Datasheets

Specifications of LM93CIMT

Peak Reflow Compatible (260 C)
No
Supply Voltage Max
3.6V
Leaded Process Compatible
No
Supply Voltage Min
3V
Operating Temperature Min
0��C
Package / Case
56-TSSOP
Operating Temperature Max
85°C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM93CIMT
Manufacturer:
NSC
Quantity:
101
Part Number:
LM93CIMT
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM93CIMT/NOPB
Manufacturer:
Intersil
Quantity:
169
Part Number:
LM93CIMTX
Quantity:
179
Part Number:
LM93CIMTX
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
LM93CIMTX/NOPB
Manufacturer:
NSC
Quantity:
400
15.0 Using The LM93
Note that since zones 1 and 2 share the same lookup table,
both zones must be operating in the same resolution mode.
The same applies to zones 3 and 4 since they share the
same lookup table.
15.10.3 Zone 1-4 to PWM1-2 Binding
Each zone must be bound to the PWM outputs in order to
have effect on the output’s duty cycle. Any combination of
the zones may be used to drive a PWM output, they are not
limited to the binding described in the previous example. For
instance zones 1, 2 and 4 may be bound to PWM1 while
zones 3 and 4 are bound to PWM2. Note that the duty cycle
levels in the lookup table are dependent on the PWM output
frequency assignment. Therefore, if PWM1 is assigned to a
high frequency and PWM2 is assigned to a low frequency, in
the binding example just mentioned, zone 4 has a different
duty cycle calculated through the lookup table for PWM1
than for PWM2, even though the same Toffset values are
used. This is due to the fact that PWM levels assigned to a
high frequency PWM output are different than the levels
assigned to a low frequency PWM output.
15.10.4 Fan Control Duty Cycles
Several registers in the LM93 use 4-bit values to represent a
duty cycle. All of them use a common mapping that associ-
ates the 4-bit value with a duty cycle. The 4-bit values
correspond also with the 14 steps of the auto fan control
algorithm. The mapping is shown below. This applies for
PWM outputs running at the default 22.5 kHz (high) fre-
quency.
15.10.5 Alternate PWM Frequencies
The PWM output can operate at lower frequencies, instead
of the default 22.5 kHz. The alternate lower frequencies can
be enabled through the PWMx Control 4 registers. When
operating in the lower frequency mode, the mapping be-
tween step numbers and duty cycles changes. This effects
the auto fan control and all LM93 registers that describe a
duty cycle using a 4-bit value.
4-Bit Value
Ah
Bh
Ch
Dh
Eh
0h
1h
2h
3h
4h
5h
6h
7h
8h
9h
Fh
Step
10
12
13
11
1
2
3
4
5
6
7
8
9
22.5 kHz (High Frequency)
Duty Cycle
(Continued)
Reserved
Reserved
100.00%
25.00%
31.25%
37.50%
43.75%
50.00%
56.25%
62.50%
68.75%
75.00%
81.25%
87.50%
93.75%
0.00%
31
The low frequency PWM output duty cycle mapping is listed
in the following table:
15.10.6 Fan Control Priorities
The automatic fan control is not the only function that influ-
ences PWM duty cycle. There are several other functions
that influence the PWM duty cycle. All the functions can be
classified into several categories:
The ultimate PWM duty cycle that is chosen can be de-
scribed by the following formula:
If (Manual PWM Override is active)
Else
So in general, categories 1, 2 and 3 are always active. In
addition to that, either category 4 or categories 5 and 6 are
active depending on whether manual override is enabled. In
this sense the manual override, when enabled, replaces
category 5 and 6.
15.10.7 PWM to 100% Conditions
There are several conditions that cause the duty cycles of all
PWM outputs to immediately get set to 100%. They are:
1. Any of the four temperature zones has exceeded the
2. The OVRID bit is set in the LM93 Status/Control.
Category
PWM = max(1,2,3,4)
PWM = max(1,2,3,5,6)
4-Bit Value
programmed Fan Boost Limit setting but has not yet
cooled down enough to drop below the hysteresis point.
#
1
2
3
4
5
6
Ch
Dh
Ah
Bh
Eh
Fh
0h
1h
2h
3h
4h
5h
6h
7h
8h
9h
PWM to 100% conditions
VRDx_HOT ramp-up/ramp-down
PROCHOT ramp-up/ramp-down function
Manual PWM Override
Fan Spin-Up Control
Automatic Fan Control Algorithm
Step
10
12
13
11
1
2
3
4
5
6
7
8
9
Category Name
Low Frequencies
Duty Cycle
Reserved
Reserved
100.00%
25.00%
28.57%
32.14%
35.71%
39.29%
42.86%
46.43%
50.00%
53.57%
57.14%
71.43%
85.71%
0%