P9PDNVL GE, P9PDNVL Datasheet - Page 27

no-image

P9PDNVL

Manufacturer Part Number
P9PDNVL
Description
FULL VOLTAGE
Manufacturer
GE
Datasheet

Specifications of P9PDNVL

Screw
INCAND
Accessory Type
Power Supply
For Use With
C-2000 Series Contactors & Starters
Overload Relay catalog numbers are shown in the shaded area in the Overload Relay Selection and Data table. To com-
plete the catalog number, replace the asterisk (*) with the appropriate digit from the shaded area in the Rating Selection
table.
Overload Relay Selection and Data
(1) Used with Overload Jumpers: CKXJ02
(2) Used with Overload Jumpers: CKXJ11 or CKXJ10
Rating Selection (Amperes)
26
0.16-0.26
0.25-0.41
0.65-1.1
14.5-18
17.5-22
Current
0.4-.65
1.3-1.9
1.8-2.7
2.5-4.1
5.5-8.5
Rating
10-16
21-26
25-32
30-40
1-1.5
4-6.3
8-12
Ambient Temperature
Auxiliary Contacts
For use with
Net Weight
Standards
Maximum
(Amperes)
Type
Rating
RT1*
Fuse
100
100
10
15
20
25
40
50
60
70
80
1
1
3
6
6
6
Man./Auto
Man./Auto
Reset
Reset
Overload Relays
Class 10
Fixed Heater
Maximum
(Amperes)
Breaker
Rating
Circuit
15
15
15
15
15
15
15
15
15
15
30
35
40
50
60
80
80
-25° to +68°C
(CL00, CL01 (CL06, CL07
CL04, CL45)
CL02, CL25
contactors
RT1* (3)
5-25 hp
11.5-15
14.5-19
18.5-25
Current
90-110
RT1*
7 oz.
Rating
24-32
30-43
42-55
54-65
64-82
78-97
Two independent double break contacts (B600, Q600)
3-pole, differential (phase unbalanced protection)
Maximum
(Amperes)
Rating
RT2*
Fuse
100
150
175
225
225
225
CL08, CL09
35
50
70
90
contactors
30-75 hp
RT2* (4)
CL10)
13 oz.
RT2*
(3) Used with Base Adapter: RTXP
(4) Used with Base Adapter: RT2XP
Maximum
(Amperes)
Breaker
Rating
VDE 0106 T100, VBG4
Circuit
100
125
150
200
225
250
25
45
60
80
100-125 hp
contactors
(CK75,
CK08)
-25° to +60°C
RT3*
RT3*
2 lb.
110-140
140-190
Current
90-120
Rating
55-80
63-90
Maximum
(Amperes)
150-250 hp
Rating
contactors
5 lb. 5 oz.
RT3*
Fuse
225
250
350
400
450
RT4* (1)
(CK09,
CK95)
RT4*
(Amperes)
Maximum
Breaker
Circuit
Rating
200
225
300
350
500
300-500 hp
contactors
RT5* (2)
(CK10,
CK11,
CK12)
RT5*
2 lb.
120-190
175-280
200-310
Current
Rating
Maximum
(Amperes)
Rating
RT4*
Fuse
600
800
900
Selection and Dial Setting
Guidelines
Motors with Service Factor of 1.15 or Greater
1. Select overload relay on the FLA as shown
2. Adjust overload relay dial to the motor
Motors with Service Factor Less than 1.15
1. Select overload relay based on the following
2. Adjust overload relay dial to the result of
REFERENCES
Trip Time Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 49-50
Overload Jumpers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 34
Instruction Sheet: RT1* . . . . . . . . . . . . . . . . . . . . . . . GEH-6237
UL File Number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E39584
CSA File Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LR45167
on the motor nameplate.
nameplate FLA.
formula: FLA shown on the motor nameplate
X 0.90. For example: if the Motor Service
Factor is 1.0, then choose the overload based
on the formula (FLA X 0.90).
the formula shown above.
(Amperes)
Maximum
Breaker
Circuit
Rating
500
700
800
120-190
175-280
250-400
315-500
430-650
Current
Rating
RT2* . . . . . . . . . . . . . . . . . . . . . . . GEH-6238
RT3* . . . . . . . . . . . . . . . . . . . . . . . GEH-6239
RT4* . . . . . . . . . . . . . . . . . . . . . . . GEH-6240
RT5* . . . . . . . . . . . . . . . . . . . . . . . GEH-6241
Maximum
(Amperes)
Rating
RT5*
1200
1200
1200
1200
Fuse
800
Maximum
(Amperes)
Breaker
Rating
Circuit
1000
1200
1200
500
700
Current
Range
Suffix
W
C
D
G
H
M
N
R
U
A
B
E
F
K
L
P
S
T
V
J

Related parts for P9PDNVL