P9PDNVL GE, P9PDNVL Datasheet - Page 33

no-image

P9PDNVL

Manufacturer Part Number
P9PDNVL
Description
FULL VOLTAGE
Manufacturer
GE
Datasheet

Specifications of P9PDNVL

Screw
INCAND
Accessory Type
Power Supply
For Use With
C-2000 Series Contactors & Starters
Accessories
Surge Suppressor (for CL contactors)
Amplifier (for CL and CK contactors)
Mechanical Latch Block (for CL contactors)
32
For suppression of disturbances in electronic circuits due to the coil transient voltage occurring on opening of the contactor.
Limits high voltage transients that may be produced when coil is de-energized. Mounts directly on the top of the coil.
Provides for 24V DC signals to operate contactor while control coils operate at the line voltage. Two forms are available: a
panel-mount form (for CK contactors) and a side-mount form (for CL contactors).
Mechanical latch block is used to convert a standard contactor into a latched contactor. Easy to mount, it clips onto front face
of contactor. Includes 1NC contact for contactor coil cut-out. Contact rating: A600 Q600.
Replace asterisk in catalog number with appropriate coil
letter designation:
Coil is rated for pulse duty only. If a continuous unlatch
signal is expected, use auxiliary contact on contactor to
disconnect unlatch coil.
For Use With
5-25 hp AC
30-75 hp AC
5-25 hp DC
5-75 hp AC/DC
For Use With
CL contactors
CK contactors (Panel Mount)
For Use With
All CL contactors
Voltage
(CL00, CL01, CL02, CL25,
CL04, CL45)
(CL06, CL07,
CL08, CL09, CL10)
(All CL contactors)
(All CL contactors)
RMLF*
RC
32V
24-
D
48V
42-
Catalog No.
G
Diode
RMLF*
125V
CR305X112P
110-
Catalog No.
J
CLXA01
Applications
50/60 Hz
Voltage
and DC
277V
208-
Varistor
N
Suppressor Type
Varistor
480V
Surge
Diode
380-
RC
RC
U
Weight
5 oz.
5 oz.
Weight
3 oz.
600V
500-
Y
Catalog No.
Input voltage .....................................19.2-26.4 Vdc
Power consumption..........................0.8 watts max.
Contact rating ...................................C600
Pickup time .......................................35-40 ms
Dropout time ....................................12-25 ms
Average expected life .......................3,000,000 operations
Mechanical Latch Block Specifications
Rated insulation voltage
Standard voltages, 50/60 Hz DC ........................24-600 V
Operating limits ..................................................nominal
Consumption for unlatching (auto cut-out) .....55 VA
Unlatching control
Mechanical life:
Unlatching pulse time (min) .............................40 ms
BSLR2G
BSLR2R
BSLR3G
BSLR3R
BSLV3G
BSLR2K
BSLR3K
BSLV3K
BSLV3R
BSLV3U
BSLDZ
(Ui) in accordance with IEC 947 ..................1000 V
Electrically ..............................Auto cut-out by integral
Manually .................................By local push button (O)
Electrically ..............................Actuated to save on
Manually .................................By push button (l)
CL00-45 ..................................3 million @ 1200/hr max
CL05-10 ....................................1 million @ 300/hr max
130-250 VAC,DC
380-500 VAC,DC
50-127 VAC,DC
24-48 VAC,DC
130-240 VAC
130-240 VAC
50-127 VAC
50-127 VAC
12-600 VDC
24-48 VAC
24-48 VAC
Voltage
contact
Contactor control
energy consumption in
contactor coil
Weight
1 oz.
1 oz.
1 oz.
1 oz.
1 oz.
1 oz.
1 oz.
1 oz.
1 oz.
1 oz.
1 oz.
voltage