P9PDNVL GE, P9PDNVL Datasheet - Page 57

no-image

P9PDNVL

Manufacturer Part Number
P9PDNVL
Description
FULL VOLTAGE
Manufacturer
GE
Datasheet

Specifications of P9PDNVL

Screw
INCAND
Accessory Type
Power Supply
For Use With
C-2000 Series Contactors & Starters
Guideform Specifications
Additional coil selections shall be available for specialized
applications.
Accessories
Timer
The timer accessory shall be mountable on the front of every
contactor up to 75hp @ 460V and shall include two contacts, one
normally open and one normally closed. Timers shall be available
in two styles, ON delay and OFF delay, and two ranges, 0.1-30
seconds and 10 to 60 seconds. The desired time shall be
adjustable throughout the range by turning a calibrated knob to a
set point. A mechanical stop will be provided to prevent adjust-
ment beyond setting range. Contact operation shall occur upon
time expiration and contact current load shall be consistent with
a heavy pilot industry duty rating of A600 P300.
Mechanical latch
The mechanical latch accessory shall be a front-mountable
device that fits every contactor up to 75hp @ 460V and shall
incorporate an electrical release coil for contactor reset. The
release coils available shall be as shown below.
Front-mount and side-mount auxiliary contacts
With just two front-mounted auxiliary contact blocks — 1NO
and 1NC — it shall be possible to achieve any combination of
auxiliaries while maintaining EN50012 numbering standards,
thus reducing inventory requirements and increasing flexibility.
Overlapping contact versions also shall be available on both front-
mounted auxiliary contact blocks.
56
• 24V-32V
• 48V-72V
• 110V-125V
• 208V-277V
• 380V-440V
• 480V-600V
60 Hz
120
208
277
240
480
600
24
48
AC Voltage
220/230
380/400
50 Hz
110
415
500
24
42
DC Voltage
125
250
12
24
48
All contactors shall accommodate the same side-mounted
auxiliary contact block. Such side-mounted auxiliary contact
blocks shall be available in 2NO and 1NO-1NC versions.
Contactors shall accommodate maximum auxiliary contacts as
shown in the following table.
Mechanical-electrical interlock
Mechanical-electrical interlocks shall fit in all contactors from
5hp to 75hp @ 460V and shall provide two built-in NC contacts.
A second mechanical interlock for all contactors 100 hp
@ 460 V and larger shall be available.
Surge suppressor
Surge suppressors shall mount directly in the upper A1-A2
coil terminals in contactors from 5hp to 75hp @ 460V without
reducing the available wiring space. The line shall provide R/C,
diode and varistor surge suppressor accessories.
Horsepower
@ 460V
100-500
20-25
30-75
5-15
Max. Aux.
Contacts
4
6
8
8
Max. Contact Block Configuration
4 front-mount or 1 side-mount on each side
4 front-mount plus 1 side-mount or 2 front-
mount plus 1 side-mount on each side
6 front-mount plus 1 side-mount or 2 side-
mount on each side
2 side-mount on each side